![Nordson Coolwave 610 Customer Product Manual Download Page 31](http://html1.mh-extra.com/html/nordson/coolwave-610/coolwave-610_customer-product-manual_1704334031.webp)
Maintenance and Repair
4-9
Part 1074165A02
E
2010 Nordson Corporation
Magnetron
NOTE:
Each lamphead contains two magnetrons.
The replacement procedure is the same for each
magnetron.
NOTE:
Magnetrons are matched during assembly
and must always be replaced as a paired set. It is
not acceptable to take one magnetron from one
pair and use it in a lamphead with a magnetron
from another pair. To help identify the pair, both
magnetrons are marked with the same serial
number.
Magnetron Removal
1. Follow steps 1
−
7 under
Internal Component
Replacement
remove the lamphead cover.
NOTE:
Be careful not to cut or damage the black
sleeving.
2. See Figure 4-17. Cut the four ties securing the
black sleeving over the high-voltage ring
terminals.
Figure 4-17 Black Sleeving
3. See Figure 4-18. Slide the sleeving down to
expose the two ring terminals. Remove the two
screws.
Figure 4-18 Ring Terminals
4. See Figure 4-19. Remove the four screws,
washers and nuts that secure the magnetron to
the lamphead base. Remove the magnetron.
Figure 4-19 Removing the Magnetron
Summary of Contents for Coolwave 610
Page 4: ...Table of Contents ii Part 1074165A02 E 2010 Nordson Corporation...
Page 12: ...Safety 1 8 Part 1074165A02 E 2010 Nordson Corporation...
Page 22: ...Installation 3 6 Part 1074165A02 E 2010 Nordson Corporation...
Page 34: ...Troubleshooting 5 2 Part 1074165A02 E 2010 Nordson Corporation...
Page 40: ...Parts 6 6 Part 1074165A02 E 2010 Nordson Corporation...
Page 43: ...Specifications 7 3 Part 1074165A02 E 2010 Nordson Corporation Figure 7 1 Lamphead Dimensions...