Installation
3-5
Part 1074165A02
E
2010 Nordson Corporation
Lamphead Cable
Connections
CAUTION:
It is important that the unicable
connectors be completely engaged and
tightened before turning on the lamp
system. Failure to properly engage these
connectors can result in damage to the UV
system.
All cables must be securely fastened. Be sure to
turn screw-type connectors until they are
completely tight against their mating receptacle.
Before inserting plugs into receptacles check both
the plug and receptacle and ensure that the rubber
inserts are in good condition and not torn. Make
sure also that there is no evidence of arcing on the
pins and sockets.
The plug is keyed and can only be inserted into the
receptacle when correctly oriented. Do not force
the plug into the receptacle.
Push the plug into the receptacle as far as it will go,
then start threading the screw ring onto the
threaded portion of the receptacle. Continue to
push on the plug while tightening the screw ring
until the plug is firmly seated into the receptacle.
Do not use the screw ring to pull the plug into the
receptacle. In some cases, it might help to wiggle
the plug slightly while pushing it into the receptacle
to ensure that all the pins mate securely with the
sockets.
Each unicable connector end features an indicator
that identifies when the connector is fully mated.
Tighten the screw ring by hand. When fully mated,
no red should appear on the indicator locations and
the is no movement between the plug and the
receptacle.
Red Indicator
−
Partially Installed
Figure 3-4
Unicable connector partially installed
No Indicator
−
Fully Installed
Figure 3-5
Unicable connector fully installed
Table 3-2 Lamphead Cable Connections
Cable
From
To
Length (ft)
Part
Unicable
Power supply unit
connector P3
Lamphead
12
775374
25
1059674
50
775375
75
755377
100
775380
Summary of Contents for Coolwave 610
Page 4: ...Table of Contents ii Part 1074165A02 E 2010 Nordson Corporation...
Page 12: ...Safety 1 8 Part 1074165A02 E 2010 Nordson Corporation...
Page 22: ...Installation 3 6 Part 1074165A02 E 2010 Nordson Corporation...
Page 34: ...Troubleshooting 5 2 Part 1074165A02 E 2010 Nordson Corporation...
Page 40: ...Parts 6 6 Part 1074165A02 E 2010 Nordson Corporation...
Page 43: ...Specifications 7 3 Part 1074165A02 E 2010 Nordson Corporation Figure 7 1 Lamphead Dimensions...