Troubleshooting
8-12
Part 1120130
E
2011
Nordson Corporation
Troubleshooting Tables
Melter Not Functioning
Possible Cause
Possible Fault / Troubleshooting
Corrective Action
1.
No line voltage
—
Connect line voltage
2.
Main power switch
not switched on
—
Place main power switch in ON
position
3.
Main power switch
defective
—
Replace main power switch
4.
Main circuit breaker
activated
—
Switch on main circuit breaker
5.
Main circuit breaker
activated again
Check for short circuit in melter or
accessories
—
6.
24 VDC power supply
defective
—
Replace
7.
Frequent melter
shutdown
Electromagnetic compatibility
disruptions
Add mains filter
One Channel (Heating Zone) Does Not Heat
Possible Cause
Possible Fault / Troubleshooting
Corrective Action
1.
Channel is disabled /
switched off
—
Enable / switch on
Summary of Contents for AltaBlue
Page 8: ...Table of Contents vi Part 1120130 E 2011 Nordson Corporation...
Page 9: ...1 Setting Up Inputs Outputs 3 18 Setting Up Gear to Line Operation 3 23...
Page 22: ...TABSHEET Introduction...
Page 30: ...Introduction 2 8 Part 1120130 E 2011 Nordson Corporation...
Page 31: ...TABSHEET Installation...
Page 58: ...TABSHEET Touchscreen...
Page 69: ...TABSHEET Operation...
Page 78: ...TABSHEET Configuration...
Page 87: ...TABSHEET...
Page 111: ...Service 7 24 Part 1120130 E 2011 Nordson Corporation Filter cartridge...
Page 112: ...TABSHEET Troubleshooting...
Page 129: ...TABSHEET Parts...
Page 188: ...Parts 9 59 Part 1120130 E 2011 Nordson Corporation This page intentionally left blank...
Page 208: ...Parts 9 79 Part 1120130 E 2011 Nordson Corporation This page intentionally left blank...
Page 214: ...Parts 9 85 Part 1120130 E 2011 Nordson Corporation This page intentionally left blank...
Page 219: ...Parts 9 90 Part 1120130 E 2011 Nordson Corporation...
Page 220: ...TABSHEET...
Page 225: ...TABSHEET Appendix A...
Page 230: ......
Page 231: ......
Page 233: ...Index i Part 123456X E 2005 Nordson Corporation Index...
Page 234: ...Index ii Part 123456X E 2005 Nordson Corporation...