A16A Inside Stripe Gun
13
Part 107907-06
E
2020 Nordson Corporation
Problem
Possible Cause
Corrective Action
1. Remotely actuated
gun fails to trigger
Poor electrical signal or connection
Check connections between timer
and solenoid valve.
Air line leaks or is blocked
Check the air line connections and
tighten if needed.
Defective solenoid valve
Check the solenoid valve, replace if
defective.
2. No flow from the
nozzle after the gun is
triggered
Dirty or blocked nozzle
Clean or replace the nozzle.
No fluid pressure in the system
Check the fluid lines and tighten if
needed. If the fluid lines do not need
to be tightened, problems may exist
in the pump. Refer to the pump
manual for troubleshooting
procedures.
3. Gun fails to turn off
Fluid pressure exceeds maximum
rating
Reduce the fluid pressure. Refer to
system manual for procedures.
4. Gun spitting fluid
Air trapped in the fluid system
Circulate fluid until air is purged from
the system.
Needle and seat are dirty or worn
Flush fluid system while triggering the
gun on and off. If spitting continues,
disassemble the gun and clean.
Replace the defective parts.
5. Gun leaking at end
cap tube fittings
Loose tube fittings
Tighten the end cap tube fittings.
Refer to
Preparing the Tubing
on
6. Gun leaking between
end cap and manifold
Loose end cap
Tighten the end cap retainer.
End cap O-ring(s) are damaged or
worn
Replace the end cap O-ring(s).
7. Gun leaking between
manifold and gun
body
Loose screws
Tighten the screws.
Manifold / End cap O-ring(s)
damaged or worn
Replace the manifold / end cap
O-ring(s).
8. Gun leaking between
gun body and seat
assembly
Loose seat assembly
Tighten the seat assembly.
Seat assembly O-ring damaged
Replace the seat assembly O-ring.
9. Gun leaking from the
gun body weep hole
Worn seal cartridge or needle or
seat
Replace the seal cartridge and
needle and seat assembly.