Ejector Gun Controller
17
E
2001 Nordson Corporation
All rights reserved
1006453A
Issued 6/01
Manual 25-23
Follow these procedures to replace the keypad on the front of the Ejector
gun controller enclosure.
1. Disconnect power at the knife disconnect and open the controller
door.
2. Unplug the communication cable (6) from the keypad (1).
3. Remove the nuts that secure the keypad to the enclosure door.
Remove the keypad from the door.
4. Install a new keypad and tighten the nuts.
5. Download the most current Ejector gun program according to your
programming software literature, using the cables supplied for
downloading.
6. Reconnect the power cable.
7. Close the controller door and restore the power connection at the
knife disconnect.
Follow these procedures to replace the power supply.
1. Disconnect power at the knife disconnect and open the controller
door.
2. Disconnect the wires going to the power supply (3).
3. Remove the power supply from the DIN rail.
4. Install the new power supply onto the DIN rail.
5. Connect the wires per the electrical schematics provided with your
system documentation.
6. Close the controller door and restore the power connection at the
knife disconnect.
Replacing the Keypad
Replacing the Power Supply