6RPHDGYLFHLQFD
se of combustion problems
Error
([SODQDWLRQ
Solution
1RGUDXJKW
The chimney is blocked
Contact a chimney sweeper / dealer for more information or clean
WKHÀXHVPRNHEDႉHDQGEXUQFKDPEHU
7KHÀXHLVVRRW\RUWKHUHLVDFFXPXODWHGVRRWRQWKH
VPRNHEDႉH
7KHVPRNHEDႉHLVZURQJO\SRVLWLRQHG
9HULI\WKHDVVHPEO\RIWKHVPRNHEDႉHVHHDVVHPEO\LQVWUXFWLRQV
7KHVWRYH
release smoke
ZKHQOLJKWLQJ
WKH¿UHDQG
GXULQJFRPEXV
-
tion
Downdraught in the room caused by no draught, that the
KRXVHLVWRR³DLUWLJKW´
/LJKWWKH¿UHZLWKDQRSHQZLQGRZ,IWKLVKHOSVPRUHELJJHUYHQWV
must be installed in the room.
'RZQGUDXJKWLQWKHURRP±FDXVHGE\H[WUDFWRUDQGRU
central ventilation system that pulls too much air out of
the room.
7XUQRႇUHJXODWHH[WUDFWRUDQGRURWKHUYHQWLODWLRQ,IWKLVKHOSV
more vents must be installed.
7KHÀXHVIURPWZR¿UHSODFHVVWRYHVDUHFRQQHFWHGWR
the same chimney at the same height.
2QHÀXHPXVWEHUHSRVLWLRQHG7KHKHLJKWGLႇHUHQFHRIWKHWZRÀXH
pipes must be of at least 30 cm.
7KHÀXHLVLQDGHFOLQLQJSRVLWLRQIURPWKHVPRNHGRPH
to the chimney.
7KHÀXHPXVWEHPRYHGVRWKDWWKHUHLVDQLQFOLQDWLRQRIDWOHDVW
10º from smoke dome to chimney. Possibly install a smoke suction
device*.
7KHÀXHLVWRRIDULQWRWKHFKLPQH\
7KHÀXHPXVWEHUHFRQQHFWHGVRWKDWLWGRHVQRWHQWHULQWRWKH
chimney but ends 5 mm before the chimney inner wall. Possibly
install a smoke suction device*.
Soot hatch in the basement or attic that is open and thus
creating a false draught.
Soot hatches must always be closed. Hatches that are not tight or
are defected must be changed.
'DPSHUWRSGUDXJKWYHQWVRUGRRUVRQ¿UHSODFHVWKDWDUH
not in use are open and create a false draught.
&ORVHGDPSHUGRRUVDQGWRSGUDXJKWYHQWVRQ¿UHSODFHVWKDWDUH
not in use.
$QRSHQKROHLQWKHFKLPQH\DIWHUWKDWD¿UHSODFHKDV
been removed, thus creating a false draught.
+ROHVPXVWEHFRPSOHWHO\VHDOHGRႇZLWKPDVRQU\
Defect masonry in the chimney, e.g. it is not airtight
DURXQGWKHÀXHSLSHHQWU\DQGRUEURNHQSDUWLWLRQLQVLGH
the chimney creating a false draught.
Seal and plaster all cracks and sites that are not tight.
The cross-section in the chimney is too large which
results in no or very low draught.
7KHFKLPQH\PXVWEHUH¿WWHGSRVVLEO\LQVWDOODVPRNHVXFWLRQ
device*.
The cross-section in the chimney is too small and the
chimney cannot carry out all the smoke.
&KDQJHWRDVPDOOHU¿UHSODFHRUEXLOGQHZFKLPQH\ZLWKDODUJHU
cross section. Possibly install a smoke suction device*.
The chimney is too low and hence a poor draught.
Increase the height of the chimney and/or install a chimney cap/
smoke suction device*.
7KHVWRYH
releases smoke
LQVLGHZKHQ
LWLVZLQG\
outside.
The chimney is too low in relationship to the surrounding
terrain, buildings, trees etc.
Increase the height of the chimney and/or install a chimney cap/
smoke suction device*.
Turbulence around the chimney due to the roof being
WRRÀDW
Increase the height of the chimney and/or install a chimney cap/
smoke suction device*.
7KHVWRYHGRHV
not heat suf-
¿FLHQWO\
7KHFRPEXVWLRQUHFHLYHVWRRPXFKR[\JHQGXHWRD
leakage under the lower border of the stove or too strong
FKLPQH\GUDXJKW'LႈFXOWWRUHJXODWHWKHFRPEXVWLRQDQG
the wood burn up too quickly.
$Q\SRVVLEOHOHDNDJHPXVWEHVHDOHGRႇ$GUDXJKWUHJXODWRURU
possibly a damper can reduce the chimney draught. NB! A leakage
of only 5 cm2 is enough for 30% of the heated air to disappear.
Too much
GUDXJKW
7KHVPRNHEXႇHULVZURQJO\SRVLWLRQHG
9HULI\WKHSRVLWLRQLQJRIWKHVPRNHEXႇHU±VHHDVVHPEO\LQVWUXF
-
tions.
In case of using oven-dried wood, this requires less air
supply than when using normal wood.
Turn down the air supply.
7KHJDVNHWVDURXQGWKHGRRUDUHZRUQDQGWRWDOO\ÀDW
Replace the gaskets, contact your dealer.
The chimney is too large.
Contact chimneysweeper or other professional for more details.
7KHJODVVLV
VRRW\
The wood is too wet.
2QO\XVHGU\ZRRGZLWKDKXPLGLW\RIPD[LPXP
The air vent control is closed too tightly.
2SHQWKHDLUYHQWFRQWUROWRDGGDLUWRWKHFRPEXVWLRQ:KHQQHZ
wood logs are inserted all vent controls should be completely
RSHQHGRUWKHGRRUVOLJKWO\RSHQHGXQWLOWKHÀDPHVKDYHDJRRG
take on the wood.
:KLWHJODVV
Bad combustion (the temperature is too low)
Follow the guidelines in this user guide for correct combustion.
Using wrong material for combustion (such as: painted
or impregnated wood, plastic laminate, plywood etc)
Ensure to use only dry and clean wood.
Smoke is relea-
VHGZKHQWKH
door is opened
A levelling out of pressure occurs in the burn chamber.
Open the air vent control for about 1 min before opening the door
– avoid opening the door too quickly.
7KHGRRULVRSHQHGZKHQWKHUHLVD¿UHLQWKHEXUQ
chamber.
Open the door carefully and/or only when there is hot ember.
:KLWHVPRNH
The combustion temperature is too low.
Increase the air supply.
The wood is humid and contains water damp.
Ensure to use only dry and clean wood.
%ODFNRUJUH\
black smoke
,QVXႈFLHQWFRPEXVWLRQ
Increase the air supply.
Summary of Contents for Uno 1
Page 11: ...52 Uno 1 mm ...
Page 12: ...53 Uno 1 mm AIR ...
Page 13: ...54 Uno 2 mm ...
Page 14: ...55 Uno 2 mm AIR ...
Page 15: ...56 Uno 4 mm 924 907 879 303 785 420 210 165 183 348 A 135 147 ...
Page 16: ...57 Uno 4 mm AIR ...
Page 17: ...58 Uno 5 mm ...
Page 18: ...59 Uno 5 mm AIR ...
Page 19: ...60 FIG 3 FIG 2 FIG 4 FIG 5 ...
Page 20: ...61 A B FIG 6 FIG 7 FIG 8 FIG 9 A B ...
Page 21: ...62 A FIG 10 FIG 11 B FIG 11A A B D E FIG 12 ...
Page 22: ...63 FIG 13 FIG 14 B A ...
Page 23: ...64 A B FIG 15 FIG 16 A B FIG 17 FIG 18 A B A B ...
Page 24: ...65 B A FIG 19 FIG 20 FIG 21 ...
Page 25: ...66 FIG 23 FIG 24 B A FIG 22 ...
Page 31: ...Nordpeis AS Gjellebekkstubben 11 N 3420 LIERSKOGEN Norway www nordpeis no ...