13
GB
$WWHQWLRQ$GMXVWLQJWKHOHJVDႇHFWVERWKWKH
WRSDQGUHDUFRQQHFWLRQKHLJKW
Flue outlet collar
8QRLVGHOLYHUHGVWDQGDUGZLWKDWRSÀXHRXWOHW
collar.
Rear connection FIG 4-10
Remove the top plate and use a 5mm Allen key to
release and remove the smoke collar FIG 4.
Loosen the screws holding the brackets for the
back plate FIG 5.
Carefully pull the brackets upwards FIG 6A and pull the
EDFNSODWHEDFNZDUGVDQGRႇ),*%
Remove the cut out in the back plate FIG 7.
Remove the rear smoke outlet cover FIG 8, and place
it over the top outlet FIG 9A. Move the smoke collar on
the back of the product and fasten it FIG 9B.
Put the back plate back in place and tighten the screws
holding it in place FIG 10
.
$GMXVWLQJWKHGRRUXQGHUWKHFRPEXVWLRQFKDPEHU
Uno 4/5
The hinges can be adjusted according to FIG 23
&RQQHFWLQJWKHÀXH
3OHDVHEHDZDUHZKHQFRQQHFWLQJWKHPPÀXHWR
WKHVPRNHGRPHWKDWWKHÀXHLVSODFHGRXWVLGHWKHÀXH
RXWOHWFROODU$OWHUQDWLYHYHUVLRQVH[VLVWGXHWR
1DWLRQDOUHTXLUHPHQWV)RUWKHÀXHFRQQHFWLRQWRWKH
chimney, follow the recommendations from the chimney
manufacturer
$LUVXSSO\
For connecting the fresh air supply set see
FIG Uno Air
1, 2 and 4/5.
3ODFHPHQWRI&(PDUN
The CE-mark which is included should be placed on the
stove.
Uno 1: The CE mark should be placed on the
back of the pedestal.
Uno 2: The CE badge should be placed on the
inside of the panel under the door.
Uno 4/5: The CE badge should be placed to the right
in the compartment under the door.
5HPRYLQJWKHVHOIFORVLQJPHFKDQLVP),*
The self closing door mechanism connected to the
stove at the bottom left corner. Carefully unhook the
spring and remove the small screw holding the arm
connected to the door. The self closing mechanism is
now deactivated.
,JQLWLRQDLUYHQWFRQWURO
As an integrated part of the air vent control, Uno has a
ignition air vent control. By pushing the air vent control
URGDOOWKHZD\EDFNPD[RSHQLQJWKHLJQLWLRQDLUYHQW
control will be activated
.
$WWHQWLRQ$IWHULJQLWLRQSXOOWKHFRQWUROEDFNWR
normal.
+
-
$ ,JQLWLRQDLUYHQW
A
/LJKWLQJWKH¿UHIRUWKH¿UVWWLPH
:KHQWKHVWRYHLVDVVHPEOHGDQGDOOLQVWUXFWLRQVKDYH
EHHQREVHUYHGD¿UHFDQEHOLW
Take care when inserting logs into the burn chamber,
in order not to damage the Thermotte plates. Please
note that there might be some humidity in the insulation
SODWHVZKLFKFDQUHVXOWLQDVORZHUEXUQUDWHWKH¿UVW
few times the insert is used. This will be resolved once
the humidity has evaporated. If needed leave the door
VOLJKWO\RSHQWKH¿UVWWLPHVWKHLQVHUWLVXVHG
It is
DGYLVDEOHWRYHQWLODWHWKHURRPZHOOZKHQXVLQJ
IRUWKH¿UVWWLPHDVWKHYDUQLVKRQWKHSURGXFWPD\
release some smoke or smell.
Both the smoke and
smell will disappear and are not hazardous.
/LJKWLQJD¿UH
Insert small, dry pieces of kindling wood, ignite and
HQVXUHWKHÀDPHVKDYHHVWDEOLVKHGRQWKHZRRG
before closing the door. Open the air vent control (FIG
2) before you close the door. Additional ignition air is
REWDLQHGE\NHHSLQJWKHGRRUVOLJKWO\RSHQ:KHQWKH
ÀDPHVDUHVWDEOHDQGWKHFKLPQH\LVZDUPWKHDLU
supply is regulated with the air vent control.
:KHQWKHUHLVDJORZLQJOD\HURIDVKQHZZRRGORJV
can be inserted. Pull the hot ember to the front of the
combustion chamber when inserting new logs so that
the wood is ignited from the front. Keep the door slightly
RSHQHDFKWLPHQHZORJVDUHLQVHUWHGVRWKDWWKHÀDPHV
JHWHVWDEOLVKHG7KH¿UHVKRXOGEXUQZLWKEULJKWDQG
OLYHO\ÀDPHV
8VLQJWKHLQVHUWZLWKORZFRPEXVWLRQHႇHFWDQG¿ULQJ
around the clock increase pollution as well as the risk
IRUD¿UHLQWKHFKLPQH\1HYHUDOORZWKHLQVHUWRUÀXH
WREHFRPHJORZLQJUHG7XUQRႇWKHDLUYHQWFRQWURO
should this happen. Regulation of the air vent control
WDNHVVRPHH[SHULHQFHEXWDIWHUDOLWWOHZKLOHDQDWXUDO
UK\WKPIRUWKH¿UHZLOOEHIRXQG
Summary of Contents for Uno 1
Page 11: ...52 Uno 1 mm ...
Page 12: ...53 Uno 1 mm AIR ...
Page 13: ...54 Uno 2 mm ...
Page 14: ...55 Uno 2 mm AIR ...
Page 15: ...56 Uno 4 mm 924 907 879 303 785 420 210 165 183 348 A 135 147 ...
Page 16: ...57 Uno 4 mm AIR ...
Page 17: ...58 Uno 5 mm ...
Page 18: ...59 Uno 5 mm AIR ...
Page 19: ...60 FIG 3 FIG 2 FIG 4 FIG 5 ...
Page 20: ...61 A B FIG 6 FIG 7 FIG 8 FIG 9 A B ...
Page 21: ...62 A FIG 10 FIG 11 B FIG 11A A B D E FIG 12 ...
Page 22: ...63 FIG 13 FIG 14 B A ...
Page 23: ...64 A B FIG 15 FIG 16 A B FIG 17 FIG 18 A B A B ...
Page 24: ...65 B A FIG 19 FIG 20 FIG 21 ...
Page 25: ...66 FIG 23 FIG 24 B A FIG 22 ...
Page 31: ...Nordpeis AS Gjellebekkstubben 11 N 3420 LIERSKOGEN Norway www nordpeis no ...