Multipurpose key
The insert is equipped with an handle, which is intended
for operating air vents.
Operational control
When the insert is in upright position, and
prior
to mounting the surround,
control that all functions
are easy to maneuver and appear satisfactory.
A. Ignition vent control
B. Air vent control
Pushed in = closed
Pull out = open
Left position = closed
Right position = open
Removing the self-closing door mechanism FIG 18
In order to deactivate - follow instruction below:
- open the door,
- lock the spring by fastening the screw - A,
- lift the door up and unfasten the screw - B,
when a noise could be heard the self-closing door is
deactivated,
- lower the door back to its place - C.
Painting the surround
It is recommended to use the insert a few times in order
to let the varnish harden before any eventual masking
and painting. Only use water based breathing paint and
a designated masking tape. Carefully remove the tape
in order not to damage the varnish.
5. Lighting a fire for the first time
When the insert is assembled and all instructions have
been observed, a fire can be lit.
Take care when inserting logs into the burn chamber, in
order not to damage the Thermotte plates.
This will be resolved once the humidity has evaporated.
If needed leave the door slightly open the first 2-3 times
the insert is used.
It is advisable to ventilate the room well when using
for the first time as the varnish on the product may
release some smoke or smell
. Both the smoke and
smell will disappear and are not hazardous.
Warning!
In order to avoid injuries, please be aware that the
surfaface may become hot during operation and
extra care need to be taken to avoid skin burn.
FIG A
FIG B
Lighting a fire
Kindling wood
Finely chopped (diameter of 3-5cm)
Length: 25-30cm
Ca. amount pr lighting : 2 kg
Place the air vent control in ignition (Pull out). Insert
small, dry pieces of wood, ignite and ensure the flames
have taken proper hold of the wood. When the flames
are stable and the chimney is warm, push in the air
control out of the ignition mode and regulate the fire
normally.
When there is a glowing layer of ash, new wood logs
can be inserted. Pull the hot ember to the sides of
the combustion chamber when inserting new logs so
that the wood is ignited from the bottom. Insert 2 logs
positioned pararelly to the glass door. The fire should
burn with bright and lively flames.
Reload size
Chopped wood (diametre of 6-9cm)
Length: 25-30cm
Normal load size. 1,55 kg /h
(Max load size: 2 kg/h)
Using the insert with low combustion effect and firing
around the clock increase pollution as well as the risk
for a fire in the chimney. Never allow the insert or flue to
become glowing red. Turn off the air vent control should
this happen. Regulation of the air vent control takes
some experience, but after a little while a natural rhythm
for the fire will be found.
WARNING:
Never leave the air control in ignition mode for pro-
longed periods as this may lead to overheating.
IMPORTANT! Always remember to open
the air vent control (preferably also the door)
before new wood logs are inserted into a hot burn
chamber. Let the flames get a good grip on the
wood before the air control setting is reduced.
When the draught in the chimney is low and
the vent is closed, the gas from the firewood
can be ignited with a bang. This can cause
damage to the product as well as the immediate
environment.
13
GB
Summary of Contents for N-21T Exclusive
Page 53: ...FIG 5 FIG 4 Left door handle assembling 3 mm Right door opening 53 ...
Page 54: ...FIG 7 FIG 6 Heat shields top a b c 60 21 30011 408 x4 a b c 60 54 ...
Page 57: ...FIG 12 1 2 1 2 FIG 13 FIG 13a 13d 57 ...
Page 58: ...FIG 13 a FIG 13 b 58 ...
Page 59: ...22 0N20T 080 x2 FIG 13 d FIG 13 c 59 ...
Page 60: ...FIG 14 1 2 FIG 15 4 mm 21 30001 516 x1 22 0N20T 161 x1 60 ...
Page 61: ...FIG 16 FIG 17 1 2 3 5 4 6 61 ...
Page 62: ...FIG 18 A 2 5 mm 2 5 mm B C Self closing door deactivation 62 ...