11
GB
IMPORTANT SAFETY PRECAUTIONS!
1. Please follow the installation manual when
connecting your stove / fireplace to the chimney /
flue pipe. If connected differently from instruction
please, consider the heat radiation from the flue
pipe to the surrounding materials.
2. Before use, please carefully read the user manual
and follow the instructions.
3. Integrated or defined convection openings may
never be reduced or partially obstructed. This may
lead to overheating, which again can cause house
fire or serious damage to the product.
4. Use only designated fire starters.
Never use
gasoline, diesel or other liquids to start the fire.
This may cause explosions!
5. Never use other fuel than natural dry chopped
wood. Briquettes, peat, coke, coal and waste
from construction materials develops far higher
temperatures and emissions than natural wood.
Since your product has been designed for use
with natural wood only, other fuels may damage
the product, chimney and surrounding
constructions.
6. In case of damage to glass or door gasket, all use
of the product must be discontinued until the
damage has been repaired.
Failure to follow these precautions will leave your
warranty void and expose people and property to
danger.
Advise:
Even if not required in your area, it is always
wise to have a qualified stove / fireplace fitter do the
installation, or at least the final inspection before use.
INDEX
1. General information about heat
accumulating fireplaces
12
Double-action damper
12
Airvent
12
Cleaning the Smoke Duct System
12
Ash
12
Weight
12
Firewall
12
Connection to chimney
12
Glue
13
Minor dents
13
Painting
13
Polishing
13
Tiles
13
Thermotte™
13
Cracks in the Powerstone™
13
2. Warranty
13
Recycling of the refractory glass
13
Packaging Recycle
13
Door and glass
13
3. Advice on lighting a fire
14
Burning Rhythm
14
Storing of Wood
14
Burning
14
Choice of fuel
15
4. Technical info
15
5. Before installing a new fireplace
16
Chimney draft
16
Shared flue gas system
16
Air supply (=mm AIR)
16
Drying Procedure
16
Combustion pace
17
6. Assembly
17
7. Some advice in case of combustion
problems
18
Summary of Contents for FP-SAL05-200
Page 46: ...46 FIG 9 FIG 8 21 30001 510 x4 3 mm IS SAL04 040 x2 21 40005 525 x2 22 SAL04 170 x2 3 mm...
Page 49: ...49 FIG 14 CO SAL05 03L 1 2 A cryl CO SAL05 03R FIG 15...
Page 57: ...57 FIG 26 LA SAL04 01L FIG 27 FIG 28 LA SAL04 01A LA SAL04 01R...
Page 59: ...59 IS SAL04 070 FIG 31 FIG 32 LA SAL04 020 FIG 33 LA SAL04 03L...
Page 60: ...60 FIG 34 LA SAL04 040 FIG 35 1 2 3 4 LA SAL04 03L...
Page 61: ...61 3 mm 2 1 FIG 36 B C A...
Page 63: ...63 FIG 38 CO SAL05 050 FIG 39 30 mm O8...
Page 65: ...65 FIG 41 a 22 SAL05 070 FIG 41 1 CO SAL05 040...
Page 68: ...68 FIG 42 PI SAL01 13B CO SAL05 050 FIG 43...