CONTROL PADS ON THE DEHUMIDIFIER
5
7
Display
Shows the set % humidity level from 35% to 85% or auto start/stop time (0~24) while setting, then shows the
actual (±5% accuracy) room % humidity level in a range of 30% RH (relative humidity) to 90% RH.
Error Codes and Protection Code:
AS
- Humidity sensor error-- Unplug the unit and plug it back in. If error repeats, call for service.
ES
- Temperature sensor of the evaporator error-- Unplug the unit and plug it back in.
If error repeats, call for service.
P2
- Bucket is full or bucket is not in right position-- Empty the bucket and replace it in the right position.
E3
- Unit malfunction-- Unplug the unit and plug it back in. If error repeats, call for service.
Other features
Bucket Full Light
Turns on when the bucket is ready to be
emptied.
When frost builds up on the evaporator coils, the
compressor will cycle off and the fan will continue
to run until the frost disappears.
Auto Defrost
Wait 3 minutes before resuming operation
After the unit has stopped, it can not restart
in the first 3 minutes. This is to protect
the unit. Operation will automatically start after
3 minutes.
Setting the Timer
When the unit is on, first press the Timer
button. The Timer Off indicator light
comes on, indicating that the Au to Stop
program has started. Press it again. The
Time On indicator light turns on, indicating
that Auto Start has begun.
When the unit is off, first press the Timer
button. The TIMER ON indicator light
comes on, indicating that the Auto Start
program has started. Press it again. The
Time Off indicator light turns on, indicating
that Auto Stop has started.
Press or hold the UP or DOWN pad to
change the Auto time by 0.5 hour incre-
ments up to 10 hours, then at 1 hour
increments up to 24 hours. The system
counts down the time remaining until
start.
The selected time will register in 5 seconds
and the system will automatically revert
back to display the previous humidity
setting.
When the Auto start & Auto Stop times are
set, within the same program sequence,
the Timer ON OFF indicator lights illuminate,
indicating that both the ON and OFF times are
now programmed.
Turning the unit ON or OFF at any time or
adjusting the timer setting to 0.0 will cancel
the Auto Start/Stop function.
When the LED display window displays the
P2 code, the Auto Start/Stop function
will also be cancelled.
Check Filter Feature
The system starts to count the time once the fan
motor turns on. The Check Filter feature can only be
activated when the accumulated operation
time reaches 250 hours or more. The Clean Filter
flashes once per second. After cleaning the air
filter, press the Filter pad and the Clean Filter light will
turn off.
Auto Shut Off
The
shuts off when the bucket is
full, or when the bucket is removed or not
in the proper position. When the humidity setting is
reached, the unit will shut off automatically.
For some models,the fan motor will continue
operating.
dehumidifier
Auto Restart
If the unit stops unexpectedly due to a loss of power,
it will restart automatically with the previous function settings
when the power resumes.