29
PROBLEM: The power does not turn on
SOLUTION:
a. Make sure that the power cord is plugged into a surge suppressor, and that the surge suppressor
is plugged into a properly grounded outlet (see page 9). Use only a single-outlet surge suppressor
that meets all of the specifications described on page 9. Important: The treadmill is not compatible
with GFCI-equipped outlets.
b. Make sure that the key is inserted into the console.
c. Check the reset/off circuit breaker located on the frame near the
power cord. If the switch protrudes as shown, the circuit breaker has
tripped. To reset the circuit breaker, wait for five minutes and then
press the switch back in.
PROBLEM: The power turns off during use
SOLUTION:
a. Check the reset/off circuit breaker (see 1. c. above). If the circuit breaker has tripped, wait for five
minutes and then press the switch back in.
b. Make sure that the power cord is plugged in. If the power cord is plugged in, unplug it, wait for
five minutes, and then plug it back in.
c. Remove the key from the console and then reinsert it.
PROBLEM: The displays of the console do not function properly
SOLUTION:
a. Remove the key from the console and
UNPLUG THE
POWER CORD.
Next, remove the screws from the hood
(not shown) and carefully remove the hood. Locate the
Reed Switch (42) and the Magnet (24) on the left side of
the Pulley (40). Turn the Pulley until the Magnet is aligned
with the Reed Switch.
Make sure that the gap between
the Magnet and the Reed Switch is about 1/8”.
If neces-
sary, use a slotted screwdriver to move the Reed Switch
slightly. Then, reattach the hood, making sure that the
Screws are inserted into the same holes from which they
were removed. Run the treadmill for a few minutes to check
for a correct speed reading.
TROUBLESHOOTING
Most treadmill problems can be solved by following the instructions in this section. Find any symptoms
that apply, and follow the steps listed. If further assistance is needed, please see the front cover of this
manual.
Reset
Off
c
24
42
Top
View
1/8”
40
a