inches (mm)
A1
A2
A3
b1
b2
b3
ROSA XXL UL-C
40 in (1016 mm)
10 in (254 mm)
15 in (381 mm)
16 in (406 mm)
8 in (203 mm)
2 in (50.8 mm)
ROSA L UL-C
40 in (1016 mm)
10 in (254 mm)
15 in (381 mm)
16 in (406 mm)
8 in (203 mm)
2 in (50.8 mm)
MILLY UL-C
40 in (1016 mm)
10 in (254 mm)
15 in (381 mm)
16 in (406 mm)
8 in (203 mm)
2 in (50.8 mm)
007098005-001
c) If the product is installed on a flammable floor, a floor protection must be installed. The floors made of flammable material,
such as moquette, parquet or cork etc., must be covered by a floor protector. SUCH FLOOR PROTECTOR SHALL BE A LISTED UL
1618 MATERIAL.
The floor protector shall be placed under the appliance and it must extend at least 16-in (419 mm) beyond the front and at least
8-in (203 mm) beyond each side of the fuel loading and ash removal opening (see
Picture 2
- distance b).
Interior Vertical Vents
Through the wall installation
A1
A2
A3
B3
A2
B2
B2
B1
A1
A2
A3
B3
A2
B2
B2
B1
Interior Vertical Vents
Through the wall installation
A1
A2
A3
B3
A2
B2
B2
B1
A1
A2
A3
B3
A2
B2
B2
B1
3.1.1 STRAIGHT INSTALLATION
3.1.2 FLOOR PROTECTION INSTALLATION REQuIREmENTS
Picture 1
Picture 2
Floor Protection
Floor Protection
15
Summary of Contents for MILLY UL-C
Page 2: ...007098005 001 2 ...
Page 36: ...4x 4x 007098005 001 1 2 36 ...
Page 37: ...4x 007098005 001 3 4 37 ...
Page 38: ...38 ...
Page 39: ...39 ...
Page 42: ...FRANÇAIS 2 007098005 001 ...
Page 76: ...4x 4x FRANÇAIS 1 2 36 007098005 001 ...
Page 77: ...4x FRANÇAIS 3 4 37 007098005 001 ...
Page 78: ...FRANÇAIS 38 007098005 001 ...
Page 79: ...FRANÇAIS 39 007098005 001 ...