A
B
ENGLISH
MAINTENANCE
FAN REPLACEMENT
.
THIS OPERATION MUST ALWAYS BE PERFORMED IN
THE ABSENCE OF ELECTRICAL POWER SUPPLY !!
-.grasp.the.diffuser.and.pull.hard.to.extract.it;
-.remove.the.4.screws.that.secure.the.motor.group.to.the.structure.
of.the.vent;
-.pivoting.on.the.left.side.of.the.motor.group.flange,.extract.the.
motor.group.from.the.vent;
.
THIS OPERATION MUST ALWAYS BE PERFORMED IN
THE ABSENCE OF ELECTRICAL POWER SUPPLY !!
-.extract.the.motor.group.from.the.vent;
-.disconnect.the.electric.wiring.
A
.for.motor.operation;
-. disconnect. the. electrical. wiring.
B
. for. operation. of. the.
temperature.probe;.
36