NORDAC SK 1000E Hardware description
12
BU1100 GB
The connection assignment U/V/W/PE is marked on the terminals. The power cables must be secured
with the supplied shielded terminals (Phoenix SK 14).
For sizes 1 and 2:
The connections terminals are suitable for a maximum
cable cross-section of
2.5mm²
. When using certain
wire sleeves, the maximum cable cross-section can be
reduced to 1.5mm².
The total external diameter of the power cable can be max.
10.5 mm, otherwise the supplied shield and strain relief
clamps cannot be fastened.
For size 3:
The connections terminals are suitable for a maximum
cable cross-section of
4mm²
. When using certain
wire sleeves, the maximum cable cross-section can be
reduced to 2.5mm².
The total external diameter of the power cable can be max.
15.5mm, otherwise the supplied shield and strain relief
clamps cannot be fastened.
vector mc
R
W
U
V
Output
+B
BB
-B
-DC
L3
L2
L1
PE L1 L2 L3
M
3 ~
X7 X8 X9
Brake resistor
Optional
(see accessories)
Line connection 3 ~ 380V - 460V
X7 X8 X9
X7 X8 X9