Installing the SK TU4-PNT-... technology unit
Modules should not be inserted or removed unless the device is free of voltage. The slots may only be used for
the intended modules.
Installation of a technology unit
separate
from the frequency inverter is not possible. It must be connected directly
to the frequency inverter.
The technology units must be
installed
as follows:
1. Switch off the mains voltage, observe the waiting
period.
2. Push the control terminals cover down slightly or
remove.
3. Remove the
blank cover
by loosening the
release on the lower edge and pulling off with an
upward turning movement.
4. Hook the
technology unit
onto the upper edge
and press in lightly until it engages.
Take care that the plug connection bar is properly contacted and if necessary fix it with a suitable
screw (self-tapping screw 2.9 mm x 9.5 mm, included in the scope of delivery of the frequency
inverter).
5. Close the control terminal cover again.