4 Synchronous motors – special information
The following supplementary or special information applies for these motors.
Pos: 141 /Anleitungen/Motoren/B1091 Drehstrommotoren/Sicherheitshinweise/Gefahr - Elektrischer Schlag - Motoren [B1091] @ 11\mod_1459952302755_388.docx @ 316085 @ @ 1
DANGER!
Electric shock
The motor is operated with a dangerous voltage. Touching certain conducting components (connection terminals
and supply cables) will cause electric shock with possibly fatal consequences.
Even when the motor is at a standstill (e.g. due to the electronic block of a connected frequency inverter or a
jammed drive unit) the connection terminals and supply cables may carry a dangerous voltage. A motor standstill
is not identical to electrical isolation from the mains.
Even if the drive unit has been disconnected from the mains, a connected motor may rotate and possibly
generate a dangerous voltage.
Installation and work must only be carried out when the motor is at a standstill and is
disconnected
(all phases
disconnected from the mains).
Follow the
5 Safety Rules
(1. Switch off the power, 2. Secure against switching on, 3. Check for no voltage, 4.
Earthing and short circuiting, 5. Cover or fence off neighbouring live components).
Pos: 142 /Anleitungen/Motoren/B1091 Drehstrommotoren/4. Synchronmotoren/Typenbezeichnung [Synchron] @ 7\mod_1431438422784_388.docx @ 219521 @ 2 @ 1
4.1 Type designation
80
D
1
/4
Number of poles
Package length: The 1..9 code depends on the axis height and the length of
the active component
Winding type: T=2100 rpm in Y circuit, 3000 rpm in ∆ circuit
Axis height: 80, 90, 100
Pos: 143 /Anleitungen/Motoren/B1091 Drehstrommotoren/4. Synchronmotoren/Anschluss [Synchron] @ 7\mod_1431438797328_388.docx @ 219553 @ 2 @ 1
4.2 Connection
Notice! Hazardous voltages occur at the motor terminals when the motor shaft is rotating!
The motors must only be operated with suitable inverters For energy-efficient operation, the inverter
must detect the position of the rotor. Various methods both with and without encoders are available for
this. See also
Motors are normally supplied with a star circuit. Some operating points can only be used in a delta
circuit. For this, the bridges must be changed according to the circuit diagram in the terminal box
cover.
Summary of Contents for B1091
Page 1: ...B 1091 en Motors Manual with installation instructions...
Page 5: ...Publisher B 1091 en 1221 5...
Page 55: ...6 Declarations of Conformity B 1091 en 1221 55 6 Declarations of Conformity...
Page 56: ...Motors Manual with installation instructions 56 B 1091 en 1221...
Page 57: ...6 Declarations of Conformity B 1091 en 1221 57...
Page 60: ...6051302 1221...