1 General
B 1091 en-1221
13
1.3.2 Installation
• After installation, screwed-on lifting lugs must be tightened or removed.
• Smooth running: Precise alignment of the clutch and a well-balanced drive element (clutch, pulleys,
fan, etc.) are prerequisites for smooth vibration-free running.
• Complete balancing of the motor and the drive elements may be necessary.
• The top section of the terminal box and the position of the terminal box can be rotated by 4 x 90
degrees.
• Even if not required, on IEC B14 motors
all four
fixing screws, must be screwed into the flanged
bearing plate! The fixing screw threads must be inserted with a sealant, e.g. Loctite 242.
WARNING
Electric shock
The
maximum
depth for screwing into the type plate is
2
x d. There is a danger that the motor windings may be
damaged if longer screws are used. This creates a danger of potential transfer to the housing and danger of
electric shock if touched.
• The motor must be inspected for damage before installation and commissioning. A damaged motor
must not be commissioned.
• Rotating shaft ends and unused shaft ends must be protected against contact. Unused parallel
shaft keys must be secured against being thrown out.
• The motor must be suitable for the installation location. (requirements prescribed by standards,
ambient conditions, installation altitude)
• Motor surfaces may become very hot during operation. Suitable protective measures must be
taken if there is a danger of contact or a hazard to the vicinity of the installation.
Pos: 26 /Anleitungen/Motoren/B1091 Drehstrommotoren/1. Allgemeines/Wuchtung, Abtriebselemente @ 7\mod_1431349031782_388.docx @ 217491 @ 3 @ 1
1.3.3 Balancing, drive elements
The fitting and removal of drive elements (clutch, pulley, gear wheel,…) must be performed with
suitable equipment. As standard the rotors are balanced with half key balancing.
The appropriate
form of balancing must be observed if drive elements are installed on the motor shaft. Drive
elements must be balanced according to ISO 1940.
The generally required measures for protection against touching the drive elements must be observed.
If a motor is started without a drive element, the parallel key must be secured against being thrown
out. This also applies for any second shaft end. Alternatively, the parallel shaft key must be removed.
Summary of Contents for B1091
Page 1: ...B 1091 en Motors Manual with installation instructions...
Page 5: ...Publisher B 1091 en 1221 5...
Page 55: ...6 Declarations of Conformity B 1091 en 1221 55 6 Declarations of Conformity...
Page 56: ...Motors Manual with installation instructions 56 B 1091 en 1221...
Page 57: ...6 Declarations of Conformity B 1091 en 1221 57...
Page 60: ...6051302 1221...