norbar TWC 1500 Manual Download Page 20

 

 

 
 
 
 
 
 
 
 

 

OPERATOR’S MANUAL 

TORQUE WRENCH CALIBRATOR (TWC) 
TWC 400 & TWC 1500 - Manual 

Part Number 34446 | Issue 2 | Original Instructions (English) 

 

NORBAR TORQUE TOOLS LTD 

Wildmere Road, Banbury, 
Oxfordshire, OX16 3JU 
UNITED KINGDOM 
Tel + 44 (0)1295 270333 
Email [email protected]  

 

 

 

NORBAR TORQUE TOOLS 

45–47 Raglan Avenue, Edwardstown, 

SA 5039 

AUSTRALIA 

Tel + 61 (0)8 8292 9777 

Email [email protected] 

 

 

 

NORBAR TORQUE TOOLS INC 

36400 Biltmore Place, Willoughby, 

Ohio, 44094 

USA 

Tel + 1 866 667 2279 

Email [email protected] 

 

 

 

 

 

 

 

 

NORBAR TORQUE TOOLS PTE LTD 

194 Pandan Loop 
#07-20 Pantech Business Hub 
SINGAPORE 128383 
Tel + 65 6841 1371 
Email [email protected] 

 

 

 

NORBAR TORQUE TOOLS (SHANGHAI) LTD 

91 Building-7F, No.1122 North Qinzhou Rd, 

Xuhui District, Shanghai 

CHINA 201103 

Tel + 86 21 6145 0368 

Email [email protected] 

 

 

 

NORBAR TORQUE TOOLS INDIA PVT. LTD 

Plot No A-168, Khairne Industrial Area, 

Thane Belapur Road, Mahape, 

Navi Mumbai – 400 709 

INDIA 

Tel + 91 22 2778 8480 

Email [email protected] 

 

 

www.norbar.com 

 

 

 

© Norbar Torque Tools Ltd 2018 

Summary of Contents for TWC 1500

Page 1: ...INC 36400 Biltmore Place Willoughby Ohio 44094 USA Tel 1 866 667 2279 Email inquiry norbar us NORBAR TORQUE TOOLS PTE LTD 194 Pandan Loop 07 20 Pantech Business Hub SINGAPORE 128383 Tel 65 6841 1371...

Page 2: ......

Page 3: ...or Kit 60327 15 FMT Quick Release Kit 60322 16 Pro Test and Static Torque Block Adaptor Kit 60323 16 TWC Angle Offset Plate Kit 60330 16 SAFETY The TWC is heavy Take care when installing Ensure the op...

Page 4: ...ilable Part Number Norbar torque measurement system Consult Norbar Static Transducer Support Kit 60318 Short Length Reaction Plate 60319 FMT Quick Release Kit 60322 FMT 25 Adaptor Kit 60327 Pro Test S...

Page 5: ...earbox designed for a sufficient balance of speed and control by allowing for both fast loading of the torque wrench and a slower more precise loading Lightweight alloy construction ensures the TWC is...

Page 6: ...ength Torque Radius Minimum 135mm 135mm Maximum 750mm 1500mm Wrench Orientation Horizontal Horizontal Calibration Direction Clockwise and Anti Clockwise Clockwise and Anti Clockwise Operating Temperat...

Page 7: ...cate the TWC on a level surface at a comfortable working height 3 Secure the feet to the bench Counter Balance Reaction Post Installation Your TWC has been delivered with the reaction counter balance...

Page 8: ...ssembly FIGURE 4 Lining up the Counter Balance Reaction Wheel Attach the counter balance wheel assembly with the two M4 socket cap screws from the underside of the top plate of the reaction assembly T...

Page 9: ...engage positively when applied This is done by pulling the lever towards you whilst at the same time winding in the screw with an appropriate screwdriver When at top dead centre the lever should start...

Page 10: ...Ensure the transducer has been fitted with the correct adaptor and place the torque wrench drive into the transducer Ensure that the torque wrench drive is fully engaged see figure 10 FIGURE 10 Attach...

Page 11: ...ld return to a true natural horizontal position FIGURE 13 Ensuring the Torque Wrench is in a Horizontal Position Ensure the TWC is at the extreme minimum of start position see figure 15 The two dots t...

Page 12: ...ON SEE FIGURE 18 Handle Use The two drive wheels offer different speeds of operation The outer drive wheel is geared to load the torque wrench 4 5 times faster than the inner wheel This is suitable fo...

Page 13: ...s it is prudent to grease the leadscrew located within the box section Greasing Procedure 1 Ensure the TWC drive wheel is in home position FIGURE 21 Extreme Minimum Position Home Position 2 Unscrew th...

Page 14: ...4 Extreme Maximum Position 5 Inject the remaining grease 6 Return TWC to the home position FIGURE 25 Extreme Minimum Position Home Position When cleaning the TWC do not use abrasive or solvent based c...

Page 15: ...nces a square drive adaptor may be required Further details below When smaller bodied static transducers are needed the reducer is used FIGURE 26 Fitting Static Transducer Support Kit Square Drive Ada...

Page 16: ...screws provided There are two mounting positions which depend on which style of transducer is being used FIGURE 28 Attaching Short Length Reaction Plate Adjust the reaction point as necessary using t...

Page 17: ...NG ENSURE BOTH HANDLES ARE BACK IN THE SEATED POSITION BEFORE USE FIGURE 30 Attaching Hexagon Adaptor Kit FMT 25 Adaptor Kit 60327 Place the adaptor plate on the TWC and secure in place with the three...

Page 18: ...cure with the QR thumb nuts FIGURE 32 Attaching FMT Quick Release Kit Pro Test and Static Torque Block Adaptor Kit 60323 Place the adaptor plate on the TWC and secure in place with the three bolts sup...

Page 19: ......

Page 20: ...INC 36400 Biltmore Place Willoughby Ohio 44094 USA Tel 1 866 667 2279 Email inquiry norbar us NORBAR TORQUE TOOLS PTE LTD 194 Pandan Loop 07 20 Pantech Business Hub SINGAPORE 128383 Tel 65 6841 1371...

Reviews: