9
Counter balance the wrench by adding weights to the carriage until the wrench is sat horizontally.
FIGURE 12 –
Adding Weights to the Counter Balance Assembly
If you push the reaction balancer up or down at the handle end the wrench should return to a true natural
horizontal position.
FIGURE 13 –
Ensuring the Torque Wrench is in a Horizontal Position
Ensure the TWC is at the extreme minimum of start position (see figure 15). The two dots to the edge of the
bearing housing denote the full travel.
To find this, wind the large drive handle anti-clockwise until stop (see figure 14).
FIGURE 15 –
Extreme Minimum Position
(Home Position)
FIGURE 14 –
Adjusting the TWC to
Minimum Position