  BioMonitor SmartLead

 

 

 

 

 

 P852 Rev B (Apr 2019)  

 

1.1 Brief Description 

 

The BioMonitor SmartLead is an accessory to the Ultium EMG sensor (#810) which is designed 
to detect the heart rate and respiration rate of the subject utilizing electrodes. The BioMonitor 
produces five simultaneous real-time data streams including ECG waveform, heart rate, R-R 
intervals, thoracic impedance (respiration) waveform, and respiration rate. 

1.2 Contraindications 

 
Use of the Ultium system is contra-indicated in individuals who have implanted pacemakers. 

2.1 Graphic Symbols and Meaning 

 

The following international icons and symbols may be found on the Ultium BioMonitor SmartLead 
enclosures and in this user manual. Their meaning is described below. 

 
 
 
               

 

                    

 
Read material in the Instruction Manual wherever this symbol 
appears. 

2.2 Glossary of Terms 

 

Ultium Sensor -- A small individual radio transmitter typically worn on the body used to measure 
and transmit bio-potential signals (such as EMG) or motion related signals (such as acceleration). 
The Ultium Systems can accommodate up to 16 body worn Ultium Sensors in one network. Two 
Ultium Systems may be used in parallel, on separate RF networks, to accommodate up to 32 
body worn sensors. 
 
Ultium SmartLead 

– Refers to different data collection modalities. Each SmartLead measures a 

given type of physical parameter. Different SmartLeads can be combined in the same Ultium 
network. The most common Ultium SmartLead is EMG. Examples of other types include 
Accelerometers, Goniometers and Force sensors. In this particular model (BioMonitor) the smart 
lead measures cardiac and respiratory signals. 
 

1 Introduction 

2 Definitions 

Summary of Contents for Ultium EMG BioMonitor SmartLead

Page 1: ...BioMonitor SmartLead P 852 Rev B Apr 2019 i Ultium Biomechanics Research System Ultium BioMonitor SmartLead User Manual...

Page 2: ...Flr Tower Street Swatar BKR 4013 Malta Website http www advenamedical com No part of this document may be copied photographed reproduced translated or reduced to any electronic medium or machine reada...

Page 3: ...dentification 5 6 2 Component Inputs Outputs and Indicators 5 6 3 Component Interconnections 6 6 4 Device Communication Driver Software Installation 6 6 5 Companion Software Installation 7 6 6 Compani...

Page 4: ...13 2 Warranty Information 16 13 3 Submitting Technical Support Requests 16 13 4 Returning Equipment 16 14 Spare Parts and Consumables 17 14 1 Consumable Items 17 14 2 Replaceable Items 17 15 Specifica...

Page 5: ...ed below Read material in the Instruction Manual wherever this symbol appears 2 2 Glossary of Terms Ultium Sensor A small individual radio transmitter typically worn on the body used to measure and tr...

Page 6: ...serial numbers Thus by serial number the Ultium system can automatically determine the type of signal parameter being transmitted from any Ultium Sensor or Ultium SmartLead in the network Multi Chann...

Page 7: ...rtLeads must be utilized in conjunction with the Ultium EMG Sensor Part 810 and the Ultium Receiver Part 880 For additional equipment details refer to Section 9 of this manual As the Noraxon Systems r...

Page 8: ...ker Never operate the Ultium BioMonitor within 1 meter of any critical medical device Warnings Do not immerse the Ultium sensors in any water or liquid Do not use the Ultium equipment on individuals u...

Page 9: ...ge Smart Lead Connector Connector for smart leads to change function of EMG sensor Status LED Sensor operational indicator flashes green when measuring Solid Yellow when charging Power Button Power th...

Page 10: ...omponent Interconnections Connect the Ultium BioMonitor SmartLead to the Ultium Designated Ultium Sensor See MR3 Configuration Section below for instructions on how to designate a sensor to a specific...

Page 11: ...Wizard s instructions 4 Double click on the icon to start the MR3 software 6 6 Companion Software Configuration Before the Ultium BioMonitor can be used with the Noraxon Ultium system the companion so...

Page 12: ...2 Click Detect Sensors in Charger All sensors which you would like to use must be in the charger this will add the SmartLead s to the list of sensors only if the unique SmartLead is connected to thei...

Page 13: ...necessary to revert to the use of the sensor s EMG functionality This will prevent configuration errors leading to the inability to collect a measurement If an error message pops up when starting a me...

Page 14: ...on ECG Respiration Rate Heart Rate and R R Interval Step 5b Continue with the measurement setup as described in the Noraxon system s hardware manual 6 6 2 Find My Sensor Feature Allows the user to qui...

Page 15: ...roperly connected If one of the sensors blinks red color the SmartLead that is connected to this sensor should be connected to another sensor It is recommended to recomplete Steps 1 5 of Section 6 abo...

Page 16: ...planted pacemaker Never operate the Noraxon Ultium System within 1 meter of any critical medical device 8 2 Normal Functions with Interface to a PC When used with the companion software the BioMonitor...

Page 17: ...utton on the Receiver to power all sensors off 8 5 Storage and Protecting Between Usages For extended storage or when travelling Place all sensors into the sensor docking station and power them off Sl...

Page 18: ...ikewise the BioMonitor SmartLead is not warranted against exposure to any of the conventional forms of sterilization 11 1 Device Software firmware updates The internal program firmware inside the vari...

Page 19: ...Patch Update file To install the Patch Update click Run on the dialog box No password is required Attention All EMG sensors should be fully charged before a firmware update is performed Symptom Proble...

Page 20: ...workmanship for 1 year from the date of purchase The warrant period begins on the date of product shipment from Scottsdale Arizona Warranty coverage does not apply to damage incurred through accident...

Page 21: ...d States Customs Noraxon USA 15770 N Greenway Hayden Loop Suite 100 Scottsdale AZ 85260 USA If you are shipping from outside the USA please use UPS FedEx DHL or EMS US Postal Service and not a freight...

Page 22: ...martLead part 852 works in line with an Ultium EMG sensor part 810 Each SmartLead is identified by a unique serial number The Ultium BioMonitor SmartLead has 3 patient contact points applied parts Two...

Page 23: ...spiratory detection is negligible this configuration is not usable for measuring respiratory rate The placement of the Ultium Sensor S is non critical ECG Standard Lead II The attachment provides a cl...

Reviews: