background image

 MyoMOTION Data Logger User Manual                                                               

 

P-2628 Rev B  

 

Section 2: Definitions

Section 2: Definitions

Section 2: Definitions

Section 2: Definitions    

Graphic Symbols and Meaning 

 

The following international icons and symbols are found on the MyoSync enclosures and in this 
user manual. Their meaning is described below. 

 

 
 
 
 

 
The device generates radio frequency energy during operation. 

 
 
 
 

 
The USB cable is applied to this connection. 

               

                

 

                    

 
Read material in the Instruction Manual wherever this symbol 
appears. 

 

                  

 

 
Identifies the manufacturer of the device. 

 

                  

 

 

 
Identifies the serial number of the device. 
 

 

                   

 

 

 
Additional information available in a separate document 

 

Glossary of Terms 

 

Pulse – A generic term for sync signal. 
 
Sync – Short for synchronization. A number of events, in this case signals, are coordinated to 
operate in unison. 
 
Sync Signal – The signal transmitted from the MyoSync that is used to coordinate all the signals. 
In MR3, the software reads the sync signals and lines everything up in unison. 

 

Summary of Contents for MyoSync 262

Page 1: ...MyoMOTION Data Logger User Manual P 2628 Rev B MyoSync User Manual...

Page 2: ...r Business Centre 2nd Flr Tower Street Swatar BKR 4013 Malta Website http www advenamedical com C C C C No part of this document may be copied photographed reproduced translated or reduced to any elec...

Page 3: ...tallation 7 Companion Software Installation 7 Companion Software Configuration 7 Section 7 Pre use Check out Normal Appearance of Signals 9 Attaching the MyoSync to a System 9 Calibration 9 Section 8...

Page 4: ...ion 15 Taking Product Out of Operation Disposal of Equipment and Batteries 17 Section 16 Specifications of the Product Expected Useful Lifetime 18 Dimensions and Weight 18 Performance Characteristics...

Page 5: ...The MyoSync receives its signal from one of two sources PC or external When connected to the PC via USB the Myosync can use this connection to generate a sync source or it can receive a sync pulse fr...

Page 6: ...e is applied to this connection Read material in the Instruction Manual wherever this symbol appears Identifies the manufacturer of the device Identifies the serial number of the device Additional inf...

Page 7: ...ons The model 262 MyoSync can accommodate a single sync in pulse and up to 5 sync out pulses and 1 inverted sync out pulse For additional equipment details refer to Section 9 of this manual As the Myo...

Page 8: ...n of signals from multiple Noraxon devices Safety Information Summary Warnings Do not expose the MyoSync to water or liquid Do not use the equipment on individuals undergoing MRI Electro Surgery or De...

Page 9: ...s have been included please see Section 9 Accessories for component identification Component Inputs Outputs and Indicators 1A MyoSync top 1 Wireless Port To plug in wireless sync transmitter module 2...

Page 10: ...r end of the USB cable CBL2 into the USB connector on the side of the MyoSync Insert the opposite end of the USB cable into an available USB port on the computer Step 2a If using an external source to...

Page 11: ...tructions given next MR3 Installation 1 Insert the MR3 USB card into the PC 2 A menu will automatically pop up 3 Click on Install MR3 and follow the Wizard s instructions Companion Software Configurat...

Page 12: ...here is no further configuration for the MyoSync but every system utilizing the sync pulse will need to be configured to accept a Sync In pulse This process will vary depending on the system but is ge...

Page 13: ...al source plugged into the external Sync In port If the Not Ready indicator is red the MyoSync is not setup properly Note When first plugged in the Not Ready light will illuminate until the setup proc...

Page 14: ...n used with the companion software the MyoSync System synchronizes the signals within the records If the user has chosen to display the sync signals they will appear as a separate channel similar to t...

Page 15: ...ries and Optional Modules Accessories and Options Part No Image Description More 228 Sync Light 262A B Wireless sync transmitter plug in module 232 Wireless Sync Transmitter 233A B Self powered wirele...

Page 16: ...http noraxon com products Interfaces to Other Devices Package Image Description Medilogic Insoles Measures foot pressure profiles using insoles Pressure Plate Stationary Measures foot pressure profile...

Page 17: ...MyoMOTION Data Logger User Manual P 2628 Rev B 13 MyoMuscle Most Noraxon EMG systems measures the biopotential signals created by the muscles...

Page 18: ...fety Precautions When Cleaning WARNING Only use a damp cloth with mild soap and water or isopropyl alcohol to clean the MyoSync system Do not immerse the enclosure in any water or liquid Cleaning by U...

Page 19: ...s or those with suitable training Companion Software Updates Perform a backup of the data folders to a separate drive as a precaution Click on the Patch Update link provided in the email or as given o...

Page 20: ...edial Action USB cable is disconnected or loose Check USB cable connection at both receiver and computer The USB port on the computer is in power save mode or a USB hub is not powered Disable the powe...

Page 21: ...vice Request can be submitted using the online form available at this link http noraxon com service request Provide all information requested by the form including a detailed description of the proble...

Page 22: ...onsumable Items None Replaceable Items Part No Image Description CBL2 USB Type A to B cable set Section 15 Taking Product out of Operation Section 15 Taking Product out of Operation Section 15 Taking...

Page 23: ...5 51 L x 2 02 W x H MyoSync Weight 3 5oz 99 2g Performance Characteristics System Coming Soon Output Transmission Frequency Depending on country Coming soon Energy Consumption Condition of Use The My...

Page 24: ...nual P 2628 Rev B 20 Section 17 Technical Information Section 17 Technical Information Section 17 Technical Information Section 17 Technical Information Block Diagram Model 262 MyoSync Coming soon The...

Reviews: