ELECTRO I
N
DUSTRI
ES,
I
N
C.
MONTI
C
ELLO,
MN 55362
NOTES:
1
USE 1" PIPING.
2
PUMP IS WITHIN IDU.
3.
ONLY R-W CONTROL REQUIRED.
4.
SEE P.1 FOR RELIEF VALVE.
5.
PUMP MUST TURN-ON WITH GAS BOILER.
6.
CHECK VALVE
7.
GAS BOILER
NORAIRE AIR TO WATER HEAT PUMP (DUAL FUEL)
-Add gas boiler, back-up. NorAire M
ode C (NI203, P.19)
- Using standard electric water heater or hydronic tank
- If water heater, suggest 35,000 BTUh m
axim
u
m
load capacity. For
larger system
s, m
u
st use sheet 6, type buffer tank.
-NorAire B/U tab controls gas boiler R & W
-After M
U
2 tim
e
out
-OT tem
p
erature below SW
OVER setting
HX103
Rev. 08 6/16/2014
Sheet 10 of 12
5.
6.
7.
1.
4.
AQUASTAT
3.
W
ODU
IDU
2.
(TANK)
HEATER
CONTROLLER
ELECTRIC WATER
ZO
NE
ZONE STATS