Operation

Installation

•  Plug the Dimmer into a power outlet. 

•  Plug the appliance into the socket of the Dimmer. The appliance must be in ON status.

• 

IMPORTANT NOTE:

 The Dimmer does not have a backup battery and will be powered down when AC power fails. 

 

DO NOT

 use the Dimmer as router for your security sensor or alarm control devices such as Door Contact, PIR Sensor…etc., 

 

otherwise the sensors will lose connection to ZigBee network if the Dimmer is disconnected from AC power. Plan the installation

 

 locations of these security sensors without using the Dimmer and only use a router with backup battery for them. 

 

The router function of the Dimmer should 

ONLY

 be used to provide signal range extension for other Power Switches/Dimmer.

Lighting Control

•  After the Dimmer has successfully joined a ZigBee network, the coordinator can remotely select different power output level to turn 
 

on/off or dim the lighting. Available options range from 0%(Off) to 100%(On)

•  You can also press the button on the Dimmer to increase the power output level. When the button is pressed, the output will increase 
 

by 10% continuously from 0% to 100%. When power out is at 100%, the dimmer will turn off to 0% and restart the cycle.

•  If you have bound a controller with the Dimmer, you can also use the controller to adjust power output level of the dimmer.

•  If the Dimmer is removed from power outlet, after replugging the Dimmer, its previous on/off status will be restored within 1 minute

Energy Consumption Monitor (PSMD-29ZBS / PSMD-29ZBSR Only)

•  The Dimmer will transmit a signal with its power consumption data every two minutes to the ZigBee network coordinator.

•  Whenever the Power Switch energy output changes by +/- 2W,, it will automatically transmit a signal with power consumption data to 
 

the ZigBee network coordinator for update.

•  The Power Switch transmits a signal with power data to coordinator whenever accumulated power usage increases by 0.1kW/hr.

•  The Meter has an accuracy of +/- 5%.

•  To clear the Dimmer of its accumulated power consumption data, follow steps below:
 

1. 

Unplug the Dimmer from power outlet.

 

2.  Press and hold the function button and plug in the Dimmer again when holding down the button.

 

3.  Keep holding the button and release after 3 seconds. The accumulated power consumption data will be cleared.

Operation Load and Lighting Type

•  For 110V: the maximum operation load is 275W and 2.5A.

•  For 230V: the maximum operation load is 575W and 2.5A. 

•  If the Dimmer is overheating, It will cut off power automatically as a safety measure. The Dimmer must be unplugged and replugged 
 

after cut off to resume normal operation.

•  The Dimmer is only compatible with incandescent and dimmable LED lighting. Fluorescent and non-dimmable LED lighting are 
 

NOT

 supported. Do not connect unsupported lighting to the Dimmer or it may cause over heating or malfunction.