4
NookBox
Installation Guide
IR 360 Detector
LED Indicator
In Normal operation mode, the LED Indicator will not light except in the following situations:
• When the Detector is in low battery condition, every time it transmits a detected movement, the LED will light up for about 2 seconds.
• When the cover is opened and the tamper switch is violated, the LED will light up for 2 sec. to indicate it is transmitting the
“
Tamper
” signal.
• When the Tamper condition persists, every time it transmits a detected movement, the LED will light up.
• When if the Detector is in Test mode, the LED will light up every time a movement is detected.
Sleep Timer
The Detector has a “
sleep time
” of approximately 1 minute to conserve power. After transmitting a detected movement, the Detector will not
retransmit for 1 minute; any further movement detected during this sleep period will extend the sleep time by another minute. In this way
continuous movement in front of a Detector will not unduly exhaust the battery.
Supervision Function
The Detector is transmits a supervisory signal once every 30 to 50 minutes. If the Control Panel fails to receive the Supervisory signals trans-
mitted from a certain Detector for a preset time, an “
Out-Of-Order
” fault message will be generated.
Sensitivity Increaser Function
You can use the sensitivity increaser function to increase the IR’s detection sensitivity. To increase detection sensitivity, please set JP3 Jumper
to
ON
position. To maintain the normal detection sensitivity, set the JP3 Jumper to
OFF position
(factory default).
Test mode
The Detector can be put into Test mode by pressing the Test Button aka LED on the front cover. In Test mode, it will disable the sleep timer
and will enable the LED indicator to flash every time a movement is detected. Each time press the Test Button, the Detector will transmit a test
signal to the Control Panel for radio range test and enter the test mode for 3 mins. It will exit Test Mode automatically after 3 mins and returns
to normal mode.