NookBox E6309744 Installation Manual Download Page 5

5

NookBox

Installation Guide

Keypad 

Power

•  Remote keypad uses one CR2 3V Lithium battery as its power source.

•  Remote keypad can also detect the battery status. If the battery voltage is low, the Active LED will flash (

Amber in Test mode or Blue 

 

in Normal mode

) during operation. The Low battery signal will be sent along with regular signal transmissions to the Control Panel for    

 

displaying the status accordingly.

•  Before shipment, the battery is pre-installed by the factory.

•  When changing battery, press the any key a couple times to discharge before inserting new battery.

Power Saving Feature

•  When idle, Remote keypad is in 

Stand-by

 mode and uses no power. It will activate and 

wake-up

 for 5 seconds when any key is pressed.

•  After 5 seconds of key inactivity, the power goes off and it returns to 

Stand-by

 mode.  

•  Upon completion of a command input, the power goes off and Remote keypad returns to 

Stand-by

 mode.

Test Mode

•  Remote keypad can be put into Test mode by entering the Keypad PIN code (default: 

0000

) followed by 

key. The Active Amber LED    

 

will turn on along with a long beep.

•  To exit Test mode, press 

 key 

twice

, Remote keypad will sound a long beep and the Active LED will turn off, then Remote keypad

 

returns to Normal Operation mode. Otherwise, Remote keypad will automatically exit Test mode after 5 minutes and return to Normal    

 

Operation mode.

<NOTE>
• 

When Remote keypad is in Test mode, it operates as 

wake-up

 condition and will NOT disconnect after 5 seconds.

Test Mode Function:

»  Press 

*

 key and then 

7

 key — Transmit Remote keypad learn signal

 

»  Press 

*

 key and then 

2

 key — Enable Dual-key Panic Alarm function 

»  Press 

*

 key and then 

3

 key — Enable Dual-key Fire Alarm function

»  Press 

*

 key and then 

4

 key — Enable Dual-key Medical Alarm function

»  Press 

*

 key and then 

5

 key — Disable all Dual Key function (Default)

»  Press 

*

 key and then 

6

 key — Edit Keypad Pin Code 

   Enter 

Old

 Keypad Pin Code and then press 

 key

  

   Enter 

New

 a new 4-digit Keypad Pin Code and then press 

#

 key.

»  Press 

 key 

twice

 — to leave the Test Mode.

»  Press 

*

 key and then 

8

 key — Enable Arm/ Home without PIN Code function

»  Press 

*

 key and then 

9

 key — Enable Arm/ Home with Control Panel User PIN Code function (

Default

)

Tamper Protection

•  The keypad is protected against any attempt to open the lid or to detach keypad from its mounting surface.

•  Tamper protection is disabled when the keypad is in Test Mode.  

Summary of Contents for E6309744

Page 1: ...1 NookBox Installation Guide Keypad NookBox Keypad P119010 E6309744 Installation Guide...

Page 2: ...2 NookBox Installation Guide Keypad NookBox Keypad P119010 E6309744...

Page 3: ...to send learn Code 11 Medical Alarm if enabled press both 7 and 9 to trigger medical alarm 12 Fire Alarm if enabled press both 4 and 6 to trigger fire alarm 13 Panic Alarm if enabled press both 1 and...

Page 4: ...5 seconds When the Active Blue LED turns off before a valid keystroke sequence is completed the previous entered keys are ignored Status LED Blue Red Red LED on the system is in Away Mode Red LED fla...

Page 5: ...long beep To exit Test mode press key twice Remote keypad will sound a long beep and the Active LED will turn off then Remote keypad returns to Normal Operation mode Otherwise Remote keypad will auto...

Page 6: ...end the learning code 2 If the Control Panel receives the learning code it will display the info accordingly Refer to the operation manual of your Control Panel to complete the learn in process 3 Afte...

Page 7: ...st mode Pressing key and then 9 key to enable Arm Home with PIN Code function Default Enter Arm Mode Enter any one of Control Panel user code and press key If panel has no fault and arming is successf...

Page 8: ...ding on Control Panel Enter Test mode Enter Keypad PIN code and then press key Panic Alarm Press 1 key 3 key at the same time if the function is enabled Fire Alarm Press 4 key 6 key at the same time i...

Page 9: ...e Home mode with Remote keypad The Status Blue LED will flash 4 times to indicate transmission error d If you input incorrect KP Pin code for 4 times KP will disable the key function for 1 minute and...

Page 10: ...10 NookBox Installation Guide Keypad For more information visit www getnookbox com...