4
NookBox
Installation Guide
Smoke Mini Detector
Features
Battery
• A 3V CR123A Lithium Battery is used to supply power to the Smoke Detector.
• The Smoke Detector has a foolproof mechanism which prohibits cover closure without first installing battery.
• When the Smoke Detector is low on battery, a low battery signal will be transmitted along with regular signal transmissions.
The Orange LED will flash with accompanying low-volume beep once every 45 seconds.
• The Red and Orange LED will flash once every 4 seconds when the battery is exhausted.
<NOTE>
When changing the battery, after removing the old battery, press the Test Button twice to fully discharge before inserting new battery.
Testing the Smoke Detector
By pressing the Test Button on the Smoke Detector, you can test if the Smoke Detector is functioning normally.
• If the Smoke Detector functions normally, the Red LED will be on for 2 seconds followed by a 2-tone beep.
• If the buzzer sounds 2-tone beeps 3 times, the “
Optical Chamber
” on the Smoke Detector is either dirty or out-of-order.
• If the Red LED doesn’t light and no beep is sounded, it means the Smoke Detector is out-of-order.
Test Mode
• The Smoke Detector can be put into Test mode by pressing the Test Button. In Test mode, it will disable the sleep timer and will
enable the LED indicator to flash every time a movement is detected. Every time the Test Button is pressed, the Smoke Detector
will transmit a test signal to the Control Panel for radio range test and enter the test mode for 3 mins. It will exit Test Mode automatically
after 3 minutes and return to normal mode.
Supervision
• The Smoke Detector will transmit a supervision signal to report its condition regularly according to user setting. The factory default
interval is 30 minutes. The user can also press the Test Button once to transmit a supervision signal manually.
Temperature Detection
The Temperature Sensor will transmit temperature signals regularly according to setting. The factory default interval is 10 minutes.
• The Smoke Detector will also send temperature signal when temperature changes by +/- 2°C.
• You can also press the Test Button once to transmit a temperature signal manually.
• The temperature detection range is about -10°C ~ 50°C.( 14°F ~ 122°F)