background image

4

NookBox

Installation Guide

Smoke Mini Detector

Features

Battery

•  A 3V CR123A Lithium Battery is used to supply power to the Smoke Detector. 
•  The Smoke Detector has a foolproof mechanism which prohibits cover closure without first installing battery.
•  When the Smoke Detector is low on battery, a low battery signal will be transmitted along with regular signal transmissions. 
 

The Orange LED will flash with accompanying low-volume beep once every 45 seconds.

•  The Red and Orange LED will flash once every 4 seconds when the battery is exhausted.

<NOTE>
When changing the battery, after removing the old battery, press the Test Button twice to fully discharge before inserting new battery.

Testing the Smoke Detector

By pressing the Test Button on the Smoke Detector, you can test if the Smoke Detector is functioning normally.

•  If the Smoke Detector functions normally, the Red LED will be on for 2 seconds followed by a 2-tone beep.
•  If the buzzer sounds 2-tone beeps 3 times, the “

Optical Chamber

” on the Smoke Detector is either dirty or out-of-order.

•  If the Red LED doesn’t light and no beep is sounded, it means the Smoke Detector is out-of-order.  

Test Mode

•  The Smoke Detector can be put into Test mode by pressing the Test Button. In Test mode, it will disable the sleep timer and will 
 

enable the LED indicator to flash every time a movement is detected. Every time the Test Button is pressed, the Smoke Detector 

 

will transmit a test signal to the Control Panel for radio range test and enter the test mode for 3 mins. It will exit Test Mode automatically  

 

after 3 minutes and return to normal mode.

Supervision

•  The Smoke Detector will transmit a supervision signal to report its condition regularly according to user setting. The factory default  

 

interval is 30 minutes. The user can also press the Test Button once to transmit a supervision signal manually.

Temperature Detection

The Temperature Sensor will transmit temperature signals regularly according to setting. The factory default interval is 10 minutes.

•  The Smoke Detector will also send temperature signal when temperature changes by +/- 2°C.
•  You can also press the Test Button once to transmit a temperature signal manually.
•  The temperature detection range is about -10°C ~ 50°C.( 14°F ~ 122°F)

Summary of Contents for E6309676

Page 1: ...1 NookBox Installation Guide Smoke Mini Detector NookBox Smoke Detector Zigbee P119037 E6309676 Installation Guide...

Page 2: ...up mo vements within an assigned area and signals the Control Panel to activate the alarm if an intruder crosses its path of detection The Smoke Detector utilizes ZigBee technology for wireless signa...

Page 3: ...ange LED Flash every second Device power on Calibration failed Flashes every 5 seconds Detecting smoke failed or device malfunctioning Flashes every 4 seconds battery exhausted Flashes every 45 second...

Page 4: ...her dirty or out of order If the Red LED doesn t light and no beep is sounded it means the Smoke Detector is out of order Test Mode The Smoke Detector can be put into Test mode by pressing the Test Bu...

Page 5: ...overage the buzzer will not sound and the LED will not flash Please refer to your Control Panel for details Alarm Silence After alarm activation the Smoke Detector can be silenced temporarily by press...

Page 6: ...minutes the LED will continue to flash during calibration Joining ZigBee network is prohibited during warm up and calibration process After calibration process the Smoke Detector will emit a 2 tone be...

Page 7: ...e following locations In a ceiling area with full view of its detection coverage unobstructed by appliances and furniture Near the entrance of a room or house to monitor entry activity Limitations Do...

Page 8: ...s if required Step 4 Align the mounting holes on Smoke Detector with the hooks on the mounting bracket Fit the Smoke Detector onto bracket and rotate clockwise to lock the hook Installation is now com...

Page 9: ...ct mesh inside the chamber and clean the chamber and mesh with brush or water Step 4 Re insert the anti insect mesh into the chamber and insert the chamber back onto the Smoke Detector Please make sur...

Page 10: ...Read only Climax Technology O 0x0005 ModelIdentifier Character String 0 32 bytes Read only Model Number O 0x0006 DateCode Character String 0 16 bytes Read only O 0x0007 PowerSource 8 bit 0x00 0xff Rea...

Page 11: ...entifier Name Type Range Access Default Mandatory Optional 0x0000 MeasuredValue Signed 16 bit Integer Min Measured Value to Max Measure Value Read only 0x00 M 0x0001 MinMeasuredValue Signed 16 bit Int...

Page 12: ...12 NookBox Installation Guide Smoke Mini Detector For more information visit www getnookbox com...

Reviews: