background image

14

15

13

Installation

Manual

Reset

If the thermostat shows an abnormal display or if you want to clear all existing programs, use a 
pointed object to press the ‘R’ key. Time and programs will need to be set again after a Reset.

  IF….                                                 THEN….

  Display will not come on                    

Check if batteries are installed correctly.

                                                             Check if batteries are fresh and of correct type.
                                                             Press the 

RESET

 key.

  Entire display flashes                         

Batteries are low. Replace with new batteries.

  Air-conditioning will not come on      

System switch is on the 

HEAT

 or 

OFF

 position.

  (symbol 

COOL

 not flashing)              

Current temperature is lower than set temperature. Press 

CURRENT

 to check current program.

                                                             Air-conditioning has been turned off within 5 minutes, and automatic delay has been activated to 
                                                             protect the compressor.

  Air-conditioning will not come on     

 Check if the air-conditioning main switch is turned on;

  (symbol 

COOL

 flashing) 

                   it may have been turned off.               

  Heating will not come on 

                  System switch is on the 

COOL

 or 

OFF

 position.

  (

HEAT

 symbol not flashing)

               Current temperature is higher than set temperature. Press 

CURRENT 

to check current program. 

  Heating will not come on                    

Check if the furnace switch and/or pilot flame is turned on; it may have been turned off.

  

(

HEAT

 symbol flashing)

                      Allow some time for the heater to heat up and the fan to activate. Most heaters will heat up the

                                                             system for a short while before warm air can be ventilated by the fan.
                                                             HE/HG jumper inside the thermostat is not set correctly. Check installation manual.

  The current temperature is                 

It is common for the setting and the displayed temperature to differ occasionally. The thermostat

 

 different from the scheduled 

             will be activated if this difference persists.

  temperature  

                                      There is a temporary override by the user.

                                                             The system is on 

HOLD

. Press 

HOLD

 once to resume normal setting.

TROUBLESHOOTING GUIDE

THM301M Installation Manual

Introduction

This thermostat can replace common residential thermostats and it is designed for use with most 
electric, oil or gas heating and air-conditioning systems that use low voltage control. Please see 
compatibility chart for more details.

!

4 weekday programs and 4 weekend programs

!

Display temperature with 0.5° resolution

!

Only two AA size batteries required (included)

!

Built-in protection timing for the air-condition compressor

If you have any questions concerning the installation or programming of the thermostat, please call 
1-888-468-6876 for our technical assistance.

Specification

Model:  THM301M
Number of Programs: Weekly 5/2 day programs with 4 programs per day
Temperature measurement range: 1
Program setting range: 5
Storage temperature range: -20

 to 50°C (-4

Battery: 2 x AA size batteries

°C - 37.5°C (34°F - 99.5°F)

°C - 35°C (41°F - 95°F)

°C

°F - 122°F)

Summary of Contents for THM301M

Page 1: ...MODEL THM301M USER S MANUAL ENGLISH DATE Oct 2 2003 THM301M Programmable Thermostat...

Page 2: ...nd switches The backlight only comes ON in the dark Any key press will turn the backlight ON for 8 seconds in the dark Features Large LCD display with backlight Real time clock showing day hour and mi...

Page 3: ...CONTROL SET CLOCK PROGRAM AHEAD RESET HOLD BACK CURRENT Function Key Descriptions LCD Display Set Time and Day Press SET CLOCK to start time setting Only time will be shown Figure 1 Use AHEAD or BACK...

Page 4: ...during winter and cooler settings during summer Program 4 this is a sleep mode You may choose to set temperature for energy savings or comfort as desired Note The 4 programs for weekdays and the 4 pro...

Page 5: ...any keys pressed for 16 seconds while setting will also return the display to normal Note The PROGRAM key can also be used anytime to review all the set programs To terminate the programming sequence...

Page 6: ...g systems from undesired on off sequences Sometimes there will be a delay of several minutes before the thermostat will activate the system Hold This feature is to hold the thermostat at a constant te...

Page 7: ...t Press both AHEAD and BACK keys together at the same time to change the time display from 12 hour format to 24 hour format e g 8 00pm 20 00 and vice versa Changing Batteries When all digits on the LC...

Page 8: ...heater to heat up and the fan to activate Most heaters will heat up the system for a short while before warm air can be ventilated by the fan HE HG jumper inside the thermostat is not set correctly Ch...

Reviews: