Replacing Old Thermostat

Note: Do not operate the cooling system when outside temperature is below 10 C (50 F) to avoid 

damaging the compressor.

!

Test the system to make sure that your heating and cooling are working properly before 
installation. If either does not work, contact your local heating/air-conditioning dealer to fix the 
problem before installation.

!

TURN OFF POWER to system at the furnace, or at the fuse/circuit breaker panel.

!

Carefully unpack your new thermostat and mounting plate; save package of screws, instructions 
and receipt.

!

Remove cover from old thermostat. If it does not snap off when pulled firmly from the bottom, 
check for a screw used to secure the cover.

!

Loosen screws holding thermostat to the wall and lift away the thermostat.

!

Disconnect wires from old thermostat or sub-base. As you disconnect each wire, use masking 
tape to label it with the old terminal designation. If there are only two wires, they don't need to be 
labeled. If there is an extra wire that is not connected to your old thermostat, then you won't need 
to connect it to the new thermostat.

!

Take care not to let the wires fall back into the wall or let the ends of the wires touch one another.

!

The wires are usually designated 'R', 'G', 'Y', 'W', 'Rc', 'C'.

°

°

Cooling Programs

Slide the system switch to the COOL position and repeat the programming as you would for the 
Heating Programs.

Temporary Override

To change the temperature temporarily, press UP or DOWN to set the desired temperature. The 
thermostat will return to the regular program at the next scheduled program time.

Note: The thermostat has an automatic delay function to protect the heating and cooling systems 
from undesired on/off sequences. Sometimes there will be a delay of several minutes before the 
thermostat will activate the system.

Hold

!

This feature is to hold the thermostat at a constant temperature and disable the set programs.

!

Press HOLD once and use UP or DOWN button to set the desired hold temperature. HOLD 
symbol will appear to indicate that the Hold function is active.

!

To cancel Hold function, press HOLD again. The current scheduled program number (P1 ~ P4). 
will appear on the screen and the HOLD symbol will disappear. The thermostat will return to the 
programmed temperature.

Check Current Programs

Press either UP or DOWN once to check the current programmed temperature setting without 
changing it. You may also use the CURRENT key for this function.

Room Temperature

!

Press DISPLAY anytime to check the current temperature.

Fan Control Switch

!

If your heating/cooling system is equipped with a fan, it will be turned on automatically when 
heating or cooling is activated. 

!

To turn on the fan manually, set the Fan ON/AUTO switch to the ON position, the fan will run 

Choosing Location For New Thermostat

Thermostat should be mounted:

!

Approximately 5 ft (1.5m) from floor.

!

Near or in a frequently used room, preferably on an inside partitioning wall.

!

On a section of wall without pipes or duct-work

Thermostat should NOT be mounted:

!

Near a window, on an outside wall, or next to a door leading outside.

!

Exposed to direct light or heat from a lamp, sun, fireplace, or other temperature-radiating 
objects which may cause false readings.

!

Near or in direct airflow from supply registers and return-air grilles.

!

Near concealed pipes and chimneys

!

In areas with poor air circulation, such as behind a door or in an alcove.

After choosing a location for the new thermostat, you may arrange to have a heating contractor 
install the control wiring for you.

Summary of Contents for THM301M

Page 1: ...MODEL THM301M USER S MANUAL ENGLISH DATE Oct 2 2003 THM301M Programmable Thermostat...

Page 2: ...nd switches The backlight only comes ON in the dark Any key press will turn the backlight ON for 8 seconds in the dark Features Large LCD display with backlight Real time clock showing day hour and mi...

Page 3: ...CONTROL SET CLOCK PROGRAM AHEAD RESET HOLD BACK CURRENT Function Key Descriptions LCD Display Set Time and Day Press SET CLOCK to start time setting Only time will be shown Figure 1 Use AHEAD or BACK...

Page 4: ...during winter and cooler settings during summer Program 4 this is a sleep mode You may choose to set temperature for energy savings or comfort as desired Note The 4 programs for weekdays and the 4 pro...

Page 5: ...any keys pressed for 16 seconds while setting will also return the display to normal Note The PROGRAM key can also be used anytime to review all the set programs To terminate the programming sequence...

Page 6: ...g systems from undesired on off sequences Sometimes there will be a delay of several minutes before the thermostat will activate the system Hold This feature is to hold the thermostat at a constant te...

Page 7: ...t Press both AHEAD and BACK keys together at the same time to change the time display from 12 hour format to 24 hour format e g 8 00pm 20 00 and vice versa Changing Batteries When all digits on the LC...

Page 8: ...heater to heat up and the fan to activate Most heaters will heat up the system for a short while before warm air can be ventilated by the fan HE HG jumper inside the thermostat is not set correctly Ch...

Reviews: