background image

8

Operating the Controls 

(cont’d.)

Speed Button

This humidifier is equipped with a
3-speed fan control. Each push of the
speed button advances the mode through
the settings of 

HIGH, MEDIUM, ULTRA

QUIET, and AUTO.

The selected setting

is displayed on the digital readout. The
higher the setting, the faster water is
evaporated and released into the air.

ULTRA QUIET

is the quietest setting and

is provided for conditions that do not
require a rapid evaporation rate.

How Auto Control Works

The 

AUTO

setting allows the humidifier to

manage it’s speed range to maintain your
desired humidity setting. It will
automatically cycle to the most efficient
speed to achieve the desired humidity.
Here is how the fan will operate:

HIGH

speed if room humidity is 10% or

greater RH (Relative Humidity) below
the 

SET

point.

MEDIUM

speed if room humidity is

10 - 5% RH below the 

SET

point.

ULTRA QUIET

speed if room humidity

is 5% or less RH below the 

SET

point.

Humidity Control

These buttons allow you to adjust the
humidity to suit your needs. This
humidifier will automatically cycle on and
off as required to maintain the selected
setting. Press the humidity buttons
to cycle the 

SET

humidity readout in 5%

increments between 25% and 65%.RH
Once you have set the desired humidity,
after 5 seconds the readout will change
to the actual room humidity.

NOTE: 

When the 

ROOM

humidity is

displayed, pressing the set humidity
buttons once will display the current 

SET

point. To increase or decrease the current

SET

point, press either the 

“+”

or

“-”

button until the desired 

SET

point is

reached.

A

SET

point of 65% RH operates the

humidifier continuously regardless of the

ROOM

reading. The humidistat that

senses the readings is located on the
power cord. Insure that it is free from
obstruction.

Humidity Up

Fan Speed

Humidity Down

Power

%

ROOM

HIGH

MEDIUM

ULTRA QUIET

REFILL

AUTO

Speed Button

%

ROOM

HIGH

MEDIUM

ULTRA QUIET

REFILL

AUTO

If the room humidity is not increasing at
the current fan speed during a 15 minute
period, the fan speed increases to the
next higher speed until the humidity 

SET

point is reached.

NOTE:

The humidifier may run on 

HIGH

for an extended period of time if the
actual room humidity is extremely low.

SP6616 NOMA HUMIDIFIER  8/4/05  11:48 AM  Page 8

Summary of Contents for CT 1201 0

Page 1: ...SP6616 Printed in Canada IMPORTANT INSTRUCTIONS NOMA Part No 43 5923 2 Model No CT 1201 0 READ AND SAVE THESE INSTRUCTIONS Evaporative Humidifier Please read the instructions carefully before using SP...

Page 2: ...egisters radiators stoves or heaters 3 Always unplug the humidifier before moving it removing the fan assembly section before cleaning or whenever the humidifier is not in service 4 Keep the humidifie...

Page 3: ...o Shut Off Yes Controls Electronic Push Button Casters Yes 4 CUL Listed Yes Volts 120 A C Hertz 60 Amps High Speed 0 80 Watts High Speed 80 Based on an area with average insulation and an 8 ceiling he...

Page 4: ...ically recommended for humidifiers Never use flammable combustible or poisonous materials to clean your humidifier To reduce the risk of scalds and damage to humidifier never put hot water in humidifi...

Page 5: ...nother location NOTE Due to release of cool moist air from humidifier it is best to direct air away from thermostat and hot air registers and to position humidifier next to an inside wall Unit should...

Page 6: ...rea If controls get wet let them dry completely and have unit checked by authorized service personnel before plugging in CAUTION Use only EPA Registered Bacteriostat Under no circumstances should you...

Page 7: ...readout Initially there is a slight delay while the electronics calibrate Two bars flash during this time Once calibration is complete a ROOM humidity reading between 20 95 will be displayed A flashin...

Page 8: ...ds This humidifier will automatically cycle on and off as required to maintain the selected setting Press the humidity buttons to cycle the SET humidity readout in 5 increments between 25 and 65 RH On...

Page 9: ...empty the red REFILL light will flash informing additional water is required Also at this time the unit will automatically switch into DRY OUT and continue to run on ULTRA QUIET speed for a 2 hour per...

Page 10: ...tage of humidity in the air It causes the humidifier to cycle on and off to maintain the selected humidity SET point The fan will turn on if the ROOM reading falls 3 below the SET point and will conti...

Page 11: ...p the housing assembly and lift straight up and away from the base and set aside The filter is now accessible 4 Take note of the filter position Remove the filter You may want to clean the base at thi...

Page 12: ...difier before cleaning or servicing If humidifier is not unplugged fan could start after housing is removed Step 3 Bi Weekly Maintenance End of Season Maintenance 1 Follow Bi Weekly Maintenance instru...

Page 13: ...ed the CK FILTER message to prematurely reset Humidifier is in DRY OUT mode Filter not dry Remedy Check 120 volt power source Press power button once to turn on Raise SET humidity level if desired A S...

Page 14: ...4 Parts List for NOMA Evaporative Humidifier NOMA Part No 43 5923 2 Model No CT 1201 0 1 2 15 16 5 6 4 15 3 11 14 7 9 8 10 13 12 12 HIGH MEDIUM ULTRA QUIET REFILL AUTO SP6616 NOMA HUMIDIFIER 8 4 05 11...

Page 15: ...866 808 6500 15 Key No Part No Description 1 830488 1 Housing Upper 2 831342 1 Assembly Control 3 829821 Blade Fan 4 830778 Motor 5 828854 Switch Micro 6 830489 Housing Lower 7 43 5925 8 Filter 8 829...

Page 16: ...SP6616 Printed in Canada 07 05 NOMA is a registered trademark of Noma Canada and is used under license FOR TECHNICAL HELP CALL 888 744 4687 Please have complete model number SP6616 NOMA HUMIDIFIER 8...

Page 17: ...Canada INSTRUCTIONS IMPORTANTES NOMA Pi ce n 43 5923 2 Mod le n CT 1201 0 LISEZ CES INSTRUCTIONS ET CONSERVEZ LES Humidificateur vaporation Veuillez lire les instructions attentivement avant d utilise...

Page 18: ...ures graves ou causer la mort ATTENTION signifie que le non respect de la consigne de s curit peut entra ner des blessures 1 Afin de r duire les risques d incendie ou de chocs lectriques branchez l hu...

Page 19: ...n 120 volts c a Fr quence 60 Hz Intensit haute vitesse 0 8 A Puissance haute vitesse 80 watt En fonction d une pi ce isolation standard ayant un plafond huit pieds de hauteur ANSI AHAM HU 1 1997 SEC 8...

Page 20: ...vient satur de l air est entra n dans l appareil pour passer dans le filtre et absorber son humidit Toute l vaporation se produit dans l humidificateur de sorte que les r sidus demeurent dans le filtr...

Page 21: ...l appareil soient orient s vers le mur L air doit p n trer dans toutes les grilles d a ration afin que l humidificateur assure un rendement optimum REMARQUE assurez vous que l humidistat se trouvant s...

Page 22: ...upape pour lib rer une petite quantit d eau Si vous entendez le bruit de bulles d eau ou remarquez des fuites autour du bouchon de remplissage lat ral ou de la valve ressort serrez un peu plus et effe...

Page 23: ...ateur de l humidificateur doit se mettre en marche lors du d marrage initial Dans le cas contraire reportez vous l anomalie Le ventilateur ne fonctionne pas afficheur num rique allum de la section D p...

Page 24: ...humidit selon vos besoins L humidi ficateur se met automatiquement sous ou hors tension selon le r glage choisi Le chiffre qui indique le niveau d humidit voulu SET varie de 25 65 et est r gl en pali...

Page 25: ...il est temps de rajouter de l eau De plus l appareil se mettra automatiquement en mode DRY OUT s chage et continuera fonctionner sur vitesse ULTRA QUIET pendant deux heures Le message DRY OUT appara...

Page 26: ...ntenir le niveau de r glage d humidit voulu Le ventilateur se met en marche lorsque le chiffre qui indique le niveau d humidit courant de la pi ce ROOM chute de 3 sous le niveau d humidit voulu SET et...

Page 27: ...fitez en pour nettoyer la base Reportez vous la section Nettoyage et entretien dans le pr sent manuel 5 Installez un nouveau filtre 43 5925 8 dans la base Enroulez le filtre et placez le entre les mon...

Page 28: ...aissez la solution reposer durant 20 minutes en remuant d licate ment toutes les quelques minutes Mouillez toutes les surfaces qui sont g n ralement expos es l eau 2 Videz la base apr s 20 minutes Rin...

Page 29: ...le mode de s chage DRY OUT Le filtre n est pas sec Correctif V rifiez la source d alimentation de 120 V c a Appuyez une fois sur la touche de mise en marche POWER pour allumer l appareil Augmentez vo...

Page 30: ...3 11 14 7 9 8 10 13 12 12 HIGH MEDIUM ULTRA QUIET REFILL AUTO Pi ces de rechange Liste des pi ces de l humidificateur vaporation NOMA NOMA pi ce n 43 5923 2 Mod le n CT 1201 0 SP6616 NOMA HUMIDIFIER 8...

Page 31: ...ce D signation 1 830488 1 Enceinte partie sup rieure 2 831342 1 Ensemble des commandes 3 829821 Pale de ventilateur 4 830778 Moteur 5 828854 Micro interrupteur 6 830489 Enceinte partie inf rieure 7 4...

Page 32: ...NOMA est une marque de commerce d pos e de la soci t Noma Canada et est utilis e sous licence POUR OBTENIR DE L AIDE TECHNIQUE T L PHONEZ AU 1 888 744 4687 Veuillez avoir le num ro de mod le port e de...