background image

5

598-1286-01

testing anD aDjustMents

1. 

Turn on the circuit breaker and light switch.

Note:

 Sensor has a 1 

1

/

2

 minute warm up period before 

it will detect motion. When first turned on wait 1 

1

/

2

 

minutes.

2.  Set:

 

ON-TIME switch to TEST

 

SENSITIVITY  dial to Midway

3.  Walk through the coverage area noting where you are 

when the lights turn on. In TEST mode, light will stay 

on for 5 seconds after sensing motion and then turn 

off.

4.  Adjust the SENSITIVITY to increase or decrease 

the range as needed. Too much sensitivity may cause 

false triggering due to heat sources in the coverage 

area (see 

Adjustment of Coverage Area or Troubleshooting

 

section).

5.  Set the amount of ON-TIME you want the light to stay 

on after motion is detected (1, 5, or 10 minutes).

  Maximum Range 

Maximum

 

 

Coverage Angle*

 

 

(Top View)

FinaL asseMBLy

1.  Push the wires into the junction box. Make sure none 

of the wires get pinched.

2.  Slide the fixture assembly onto the mounting screws. 

Tighten decorative nuts removed in step 1 of 

Installation 

section securely against fixture base.

Junction Box

Mounting Screw

Decorative Nut

3.  Install one medium base light bulb (100 Watt maxi-

mum).

4.  Place top cover onto fixture and attach using the two 

decorative nuts (included). Hand tighten only.

5.  After completing the tests on page 5, caulk around 

fixture base with silicone weather sealant.

Top Cover

Decorative Nut

Light Bulb (100 

Watt Maximum)

Fixture Assembly

Caulk Around 

Fixture Base

TEST   1  5   10

            MINUTE

            +

              SEN

30 ft.

(9.1 m)

6 ft.

(1.8 m)

180°

Summary of Contents for Carriage Light with Motion-activated 52-4473-6

Page 1: ...Attachreceiptincaseofpossible warranty issues Model Number Requirements The Light Control requires 120 volts AC If you want to use Manual Mode the control must be wired through a switch Someelectrica...

Page 2: ...er lights from the motion sensor see Optional Wiring Note All wiring must be run in accordance with the Canadian Electrical Code through conduit or another acceptable means Contactaqualifiedelectricia...

Page 3: ...ith the bare fixture wire and the box ground wire Secure with a wire connector Secure the other end of the pigtail with the GND screw on the X bar Black to black White to white Ifyouhavemetaljunctionb...

Page 4: ...hite wires together Total fixture ratings must not exceed 360 Watts 3 0 A Wiring Diagram 2 When wiring to control another motion sensing light fixture Master Slave Strip the red wire in both light fix...

Page 5: ...ing section 5 SettheamountofON TIMEyouwantthelighttostay on after motion is detected 1 5 or 10 minutes Maximum Range Maximum Coverage Angle Top View Final Assembly 1 Push the wires into the junction b...

Page 6: ...If you get confused while switching modes turn the power off for one minute then back on After the calibration time the control will be in the AUTO mode MANUAL MODE Adjustment of Coverage Area The sen...

Page 7: ...y dark location 2 Light control is in TEST 1 The fixture is operating normally under these condi tions 2 Set control switch to 1 5 or 10 minutes Lights come on for no apparent reason 1 Light control m...

Page 8: ...tre reli e un interrupteur Dans certaines localit s le code de l lectricit exige que l installation soit confi e un lectricien quali fi Veuillez v rifier les codes en vigueur dans votre r gion Avant l...

Page 9: ...teurdemouvement voir C blage Facultatif Note Le c blage doit tre conforme aux exigences du Code canadien de l lectricit et tre install dans des canalisations ou autres dispositifs acceptables Si vous...

Page 10: ...re et lefildeterredelabo tedejonction Utilisezunserre fils Fixez l autre extr mit de la queue de cochon avec la vis de terre GND sur la plaque de montage noir noir blanc blanc Si la bo te de jonction...

Page 11: ...age 2 C blage d un autre luminaire d tecteur de mouvement Ma tre Satellite d nudez le fil rouge des deux luminaires Branchez le fil rouge du luminaire de commande ma tre aux fils rouge et noir du lumi...

Page 12: ...un mouvement 1 5 ou 10 minutes Note Le capteur exige 1 1 2 minute avant de d tecter les mouvements Lors de la premi re mise sous tension attendez 1 1 2 minute Port e maximale Angle de couverture maxi...

Page 13: ...nde plus en circuit pour alterner entre les modes AUTO et MANUEL Lemodemanuelnefonctionne que lorsque l interrupteur ON TIME est aux positions 1 5 ou 10 R sum du mode de commutation Mettrel interrupte...

Page 14: ...e 2 Le r glage de port e est trop lev 1 R duisez la port e 2 R duisez la port e L clairage demeure al lum continuellement 1 Lecapteurpeutpercevoirunesourcedechaleur comme une sortie d air un vent de s...

Page 15: ..._ __________________________________ __________________________________ __________________________________ __________________________________ __________________________________ _______________________...

Page 16: ..._ __________________________________ __________________________________ __________________________________ __________________________________ __________________________________ _______________________...

Reviews: