When the control board is powered, the lights “ l.e.d. are situated in the outputs, they are switched on when on the output

there is a closed contact to the common.

Normally the 

red l.e.d

. in the inputs 

“Closing limit switches” (FCC) , “opening limit switches”(FCA), STOP, FOTO

 

are always 

SWITChED ON.

Normally the 

green l.e.d.

 in the inputs 

START and PEDONALE 

(partial opening) are 

switched OFF

2.5  Description of the connections

4

230 Vac Neutral

1

230 Vac electrical power supplì 50 Hz Neutral

EARTH

2

EARTH

230 Vac Phase

3

230vac electrical power supply 50 Hz Phase

Lamp

4

Outputs for LAMP (flashing light electronic card) or 230 VAC COURTESY LIGHT

Lamp

5

M  1  Com

6

Output for the connection of motor 1 COMMON POLE M 1

M 1 Opening

7

Output for the connection of motor 1 POLE OPEN MOTOR 1

M 1 Closing

8

Outputs for connections motor no.1 pole CLOSE

M  2  Com

9

Output to connect motor no.2 pole common M2

M 2 Opening

10

Output to connect motor no.2 pole OPEN M2

M 2 Closing

11

Output to connect motor no.2 pole CLOSE

FCC  M2

12

Input Closing limit switches motor no.2

FCA  M2

13

Input Opening Limit Switches 2

FCC  M1

14

Input for Closing limit switches of motor no.1

FCA  M1

15

Input for opening limit switches of Motor 1

Photocells  A

16

Input Photocell A , working only by closing (see chapter 2.3)

START

17

Input for step-by-step function START

24Vac

18

Output for 24 Vac

24Vac / 12Vac

19

Output for electrical lock 12 Vac 50 Hz 1A

12Vac Lock

20

Output for electrical lock 12 Vac 50 Hz 1A

STOP

21

Pedestrian Stop input

PEDONALE

22

Input for step-by-step function PEDESTRIAN partial opening

Photocells  B

23

Input for photocells B working in Closing and in opening (see chap. 2.3)

Common 1

 -

24

Common for all inputs: services, Securities, coaxial antenna cable sock.

A

25

Input for antenna (antenna cable)

light or lamp

26

Contact for Light or LAMP (without electronic card)

light or lamp

27

Contact for Light or LAMP (without electronic card)

PHOTOTEST

28

Output TEST FOR PHOTOCELL 12 Vac

12Vac

29

Output 12Vac

24Vdc +

30

Output 24Vdc +

Comm.

  24Vdc  -

31

Output 24Vdc - Common for inputs: services and safety

Summary of Contents for START-S4XL

Page 1: ...230 Vac Lamp Motor 1 COMMON Motor 1 OPEN Motor 1 CLOSE Motor 2 COMMON Motor 2 OPEN Motor 2 CLOSE Open Limit Switch Mot 2 Clos Limit Switch Mot 1 Closing photocell Start Button 24Vac 24 Vac 12Vac elec...

Page 2: ...ical limit switches should fail or during manual operations 2 Installation 1 Introduction START S4XL is the ongoing evolution of the START S4 electronic control unit completely compatible and equipped...

Page 3: ...75 mm2 Use shielded cables if the length exceeds 30m and connecting the ground braid only from the side of the control unit Do not connect the cables in underground cases even if they are water tight...

Page 4: ...OPEN M2 M 2 Closing 11 Output to connect motor no 2 pole CLOSE FCC M2 12 Input Closing limit switches motor no 2 FCA M2 13 Input Opening Limit Switches 2 FCC M1 14 Input for Closing limit switches of...

Page 5: ...and if adjusted at the maximum power the door opens when the second door has finished the working time In next opening will the new value valid 0 Max SPEED SLOW DOWN Setting up of the speed of the sl...

Page 6: ...8 9 10 1 2 7 3 ON REVERSING STROKE This function starts a closing thrust at the beginning or at the end of the manoueuvre to make easy the work of the electrical lock 4 ON Courtesy light In the output...

Page 7: ...pening displacement will be at 2 seconds The closing displacement can be chosen with the trimmer displacement 7 X Leave in the OFF 8 OFF Time learning planned from the user Leave in OFF when used the...

Page 8: ...put photocell always activated 8 ON Radio DECODE It activate the radio receiver 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 8 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7...

Page 9: ...ry all codes is possible only when the gate is closed 1 Make sure that the gate is in closed position 2 Push the codes button until the L E D CODICE flashes AND release it Wait until the reset of the...

Page 10: ...nt time the first motor closes 5 Press the TIMES button or START if the limit switches are not available The second motor stops wait until the first motor stops END OF LEARNING TIME if the limit switc...

Page 11: ...switch of motor no 2 is not available The second motor stops the first motor CLOSES 9 a if the limit switch is available wait until motor no 2 stops The motor no 2 stops motor no 1 closes 10 Push the...

Page 12: ...ls for the TEST function Now the control unit check the TEST function of all devices and the the gate opens with a little bit delayed 8 6 9 10 7 8 Make all connections to the TEST as shown in the manu...

Page 13: ...989 harmonizing the legislation of the member countries regarding electromagnetic compatibility Reference to harmonized standards EN 61000 6 2 EN 61000 6 3 THE PRODUCT COMPLIES with the essential requ...

Page 14: ...sous la seule responsabili du constructeur et si applica ble de son repr sentant autoris Busto Arsizio Va Italia 14 06 2007 ERNESTINO BANDERA Administrateur KONFORMIT TSZERTIFIKAT Der Unterzeichner be...

Reviews: