General instructions for RH-59 GSM TX troubleshooting
Apply a RF-cable to the RF-connector to allow the transmitted signal act as normal. RF-cable
should be connected to measurement equipment or to at least a 10-dB attenuator, otherwise
the PA may be damaged.
Start Phoenix-Service-Software and establish a connection to the phone e.g. FBUS.
Select File and Product: RH-59
Select: Maintenance, Testing and RF Controls
Band:
GSM 900
Active Unit:
TX
Tx Power Level:
19
Tx Data Type:
All 1
Your screen should look like:
Figure 42:GSM900 RF controls window
Measure the output power of the phone; it should be around 32.1 dBm.
Remember the loss in the jig; around 0.3 dB.