![Nokia RH-37 Series Service Software And Tuning Instructions Download Page 51](http://html.mh-extra.com/html/nokia/rh-37-series/rh-37-series_service-software-and-tuning-instructions_1699385051.webp)
Nokia Custome Care
Service Sofftware and Tuning Instructions
RH-37
Issue 1 07/04
Nokia Corporation
Page 51
If a radio communication tester (CMD 55, CMU 200, HP 8960, MT 8801) is used, assure
that <continuous mode> is switched on and <modulation> switched off.
Compensate for external RF cable and test jig losses.
Make sure that the <Input Signal Level (dBm)> field is set to -60 [dBm].
Press the <Start> button in the <Rx Band Filter Compensation> window.
The setup should now look like this:
(The example below shows a screen shot in GSM900!)
Set the RF signal generator as indicated in the pop-up window on the screen.
Press
OK
.
Continue tuning steps 2 to 9 following the instructions for power level and signal fre-
quency input.
Press
OK
after each step.
Note the limits as specified in the table below.
Press
Save & Continue