![Nokia RH-29 Series Manual Download Page 68](http://html.mh-extra.com/html/nokia/rh-29-series/rh-29-series_manual_1699380068.webp)
RH-29
Company Confidential
6b - RF Troubleshooting
Nokia Customer Care
Page 40
Copyright
©
2004 Nokia Corporation
Issue 1 05/2004
Company Confidential
Wait until phone information is shown in the lower right corner of the screen.
Now you can change values for path losses and select right jig for the prouct.
Select
Tuning
Alt-u
Set Loss
o
Set losses for RF-cables as shown in figure below:
Figure 16: Set loss for RF-cable(s)
Select used test jig (MJ-21) for the product, from the “Product” menu. If MJ-21 is not
there, you have to add it. See figure below:
Figure 17: Add jig for the product