6b - RF Troubleshooting
Company Confidential
RH-29
Issue 1 05/2004
Copyright
©
2004 Nokia Corporation
Page 33
Company Confidential
The Spectrum Analyzer now shows a plot like this:
Use the variables ‘Amplitude difference’ and Phase difference’ to adjust the +67KHz sig-
nal to a minimum level (Marker 3). After tuning to the minimum the level difference
between the peak levels at marker 1 and 3 must exceed 40dB, Tuning is possible by using
arrow keys on the keyboard. Pushing the sliders by using the mouse is less sensitive but
even possible’