CCS Technical Documentation
Baseband Troubleshooting Instructions
Issue 1 10/02
¤
Nokia Corporation
Page 49
Audio
faults 2
Is microphone working?
Try change bottom
connector X100.
Is it working now?
Retest
No
Yes
Set phone in LOCAL mode.
Use Phoenix Audio Test.
Set HP IN, EXT OUT, LOOP ON.
No
Measure MICB1
voltage from MICP pads.
Is it ~ 2.1 V?
Check L105,
C105, C152,
C156, R152,
C168, C166,
C215, and line.
If OK ->
change UEM.
No
Check C151,
R157, C105,
C154, and line.
If OK ->
change UEM.
Yes
Audio
faults 3
Yes