NEM-4
Company Confidential
RF Troubleshooting
CCS Technical Documentation
Page 6(b)-66
Copyright
2003 Nokia Corporation
Issue 1 09/2003
Company Confidential
Select
Testing
alt-S
RF Controls
R
Wait until the RF Controls window pops up
Select
Band
GSM 900 or GMS1800 or GSM1900
Active unit
RX
Operation mode
continuous
RX/TX Channel
37 or 700 or 661
AGC
14
Following picture should be seen on a working EGSM receiver:
Signal amplitude
1.25V
DC offset
1,35V
Frequency
67kHz
Receiver fault finding
Set up Phoenix as if doing RSSI measurements.
Ascertain which Rx band is faulty.
Refer to Rx fault finding flow chart.
Set signal generator frequency to 942.47MHz for EGSM, 1842.87MHz for DCS 1800 or
1960.07MHz for PCS 1900.
Set signal generator amplitude to -60dBm.
Note:That checking the RF inputs to SAW filters Z602, Z603 & Z604 will be extremely difficult with