![Nokia NEM-4 Series Troubleshooting Instructions Download Page 68](http://html.mh-extra.com/html/nokia/nem-4-series/nem-4-series_troubleshooting-instructions_1699285068.webp)
NEM-4
Company Confidential
RF Troubleshooting
CCS Technical Documentation
Page 6(b)-64
Copyright
2003 Nokia Corporation
Issue 1 09/2003
Company Confidential
Select
Band
GSM 900 or GMS1800 or GSM1900
Active unit
RX
Operation mode
Burst
RX/TX Channel
37 or 700 or 661
Select
Testing
alt-S
SNR Measurement
N
select Fast SNR
Radio Button
The setup should now look like this:
Choose respective band (EGSM900, GSM1800, GSM1900)
Press Start. A window pops up, e.g. for EGSM900 band:
Connect an external signal generator to the RF connector of the phone and set the gen-
erator as told in the window, taking care for external cable losses.