NEM-4
Company Confidential
RF Troubleshooting
CCS Technical Documentation
Page 6(b)-104
Copyright
2003 Nokia Corporation.
Issue 1 09/2003
Company Confidential
GSM1900 (PCS)
Set the generator as instructed and press OK.
A typical result will look like this:
Press Save and Continue. RX Calibration is finished and the tuning is fully completed.
RX AGC limits
The Rx calibration is only valid if it is within certain limits.
For the most recent limits see NEM-4 Production Testing Requirements,
If calibration is not within limits, there is a fault in the RX chain.