Replacing units
DN9913495
© Nokia Corporation
Draft
41 (52)
Issue 3-0 en
Nokia Proprietary and Confidential
Note
2.
Unclip and slide the cable cover towards you.
3.
Disengage and remove the cable cover support plate.
4.
Remove all connecting cables to the units. If necessary, make a note of the
cable connections before removing them.
All connecting cables must be removed in order to remove the fan mounting
assembly.
5.
Detach the outer sealing gasket at the point where it covers the cable entry
block, see (A) in Figure 10.
6.
Remove the two 4 mm (0.157 in) Allen screws on the cable entry block.
See (B) in Figure 10.
7.
Open the cable entry block at the point where the cables are routed.
8.
Disengage the cables from the cable entry block.
Figure 10.
Displacing the sealing strip and releasing the cables
A
Sealing strip
Allen screws
M6
Allen key 4 mm