Maintenance
24 (52)
© Nokia Corporation
Draft
DN9913495
Nokia Proprietary and Confidential
Issue 3-0 en
5.2
Troubleshooting checklist
Table 2.
Troubleshooting checklist
Symptom
Possible fault
Action
BTS is powered ON but
the BTS Manager
connection cannot be
established.
1. Master TRX broken.
1. Replace the master
TRX with one of the slave
TRXs and insert a new
TRX into the slave TRX’s
slot. Refer to Section
6.4.3.
2. Interface unit broken.
2. Replace the interface
unit.
3. Wrong BTS Manager
port setting (COM 1, COM
2).
3. Correct the COM port
settings.
4. LMP cable broken or
not properly connected.
4. Check the connection
before replacing the cable.
No power to the BTS.
1. Fault in the site mains
power supply.
1. Check the site’s mains
power source and fuses.
Replace if necessary.
2. Broken power cable.
2. Replace the cable.
3. Power supply unit
broken.
3. Replace the power
supply unit.
4. Short circuit in one of
the BTS units.
4. Pull the units out one by
one until the power comes
back on. Start from the
TRXs and proceed to the
transmission unit, fan unit
and finally to the interface
unit. Return the units one
by one and replace the
faulty unit(s).
5. Power supply unit
switch in stand-by
position.
5. Turn the PSU’s switch to
the ON position.
6. Cold start active.
6. Wait until the units have
warmed up to the
operational temperature
range and the power
supply unit LED turns
green.