![Nokia 6260 RM-25 Service Manual Download Page 23](http://html.mh-extra.com/html/nokia/6260-rm-25/6260-rm-25_service-manual_253259023.webp)
Standby time
Battery: BL-4C 760mAh
Up to 100-150 hours
Note:
Variation in operation times will occur depending on SIM card, network settings and usage. Talk
time is increased by up to 30% if half rate is active and reduced by 5% if enhanced full rate is active.
Environmental conditions
Environmental
condition
Ambient temperature
Notes
Normal operation
15
o
C ... +55
o
C
Specifications fulfilled
Reduced performance
55
o
C ... +70
o
C
Operational only for short periods
Intermittent or no
operation
-40
o
C ... -15
o
C and +70
o
C ... +85
o
C
Operation not guaranteed but an
attempt to operate will not damage
the phone
No operation or
storage
<-40
o
C and >+85
o
C
No storage. An attempt to operate
may cause permanent damage
Charging allowed
-15
o
C ... +55
o
C
Long term storage
conditions
0
o
C ... +85
o
C
Humidity and water
resistance
Relative humidity range is 5 to 95%.
Condensed or dripping water may
cause intermittent malfunctions.
Protection against dripping water has
to be implemented in (enclosure)
mechanics.
Continuous dampness will cause
permanent damage to the module.
RM-25
General information
Nokia Customer Care
9235618 (Issue 2)
Company Confidential