Nokia 6090 AT Command Set
56
+IFC DTE-DCE Local Flow Control
This command is used to control the operation of local flow control between the DTE
and the Nokia 6090. <DCE_by_DTE> specifies the flow control used by the DTE to
control the flow of received data from the Nokia 6090. <DTE_by_DCE> specifies the
flow control used by the Nokia 6090 to control the flow of transmitted data from the
DTE.
Syntax:
AT+IFC=[<DCE_by_DTE>[,
<DTE_by_DCE>]]
Set flow control.
Default is 2,2.
AT+IFC?
Query current setting.
Response is +IFC: <DCE_by_DTE>,
<DTE_by_DCE>.
AT+IFC=?
Show valid range of parameters.
Response is+IFC:(list of supported
<DCE_by_DTE>'s), (list of supported
<DTE_by_DCE>'s)
Parameters:
<DCE_by_DTE>
0
no flow control
1
XON/XOFF (software) flow control
2
CTS/RTS (hardware) flow control
3
both XON/XOFF and CTS/RTS flow
control
<DTE_by_DCE>
0
no flow control
1
XON/XOFF (software) flow control
2
CTS/RTS (hardware) flow control
+ILRR DTE-DCE Local Rate Reporting
This command controls whether or not the +ILRR:<rate> information text is
transmitted to the DTE. If enabled, the result code is transmitted after any
modification, error control or data compression reports are transmitted, and before
any final result code (e.g., CONNECT) is transmitted. The <rate> is applied after the
final result code is transmitted. (V.25ter)
Syntax:
AT+ILRR=<mode>
Set reporting mode.
Default is 0.
AT+ILRR?
Query current setting.
Response is +ILRR: <mode>.
AT+ILRR=?
Show supported values.
Response is +ILRR:(list of supported
<mode>'s)
Values for <mode>:
0
local port rate reporting disabled
1
local port rate reporting enabled