![Nokeval FTR970-PRO User Manual Download Page 24](http://html1.mh-extra.com/html/nokeval/ftr970-pro/ftr970-pro_user-manual_1699205024.webp)
Logger
Channels
Other periodic
Sporadic
Unknown
Channel
interval [s]
Flash erase
Clock
Clock
Run
Year
Month
Day
Hour
Min
Sec
24
Channels
Choose if channels are to be saved into the fl ash
memory
Channels
are devices whose IDs have been confi gured
in the channel table in menu and are of type which can
be used as a channel. See previous table.
Other periodic
Choose whether devices, which could be channels but
are not confi gured in channel table in menu, are to be
saved in fl ash memory.
Sporadic
Choose whether devices, which could not be channels,
are to be saved in fl ash memory.
Unknown
Choose whether devices which are unknown (those de-
vices which are designed after FTR970-PRO software
version) are to be saved in fl ash memory.
Channel interval
This setting sets whether interval logging is on.
If setting is 0, interval logging is not in use. Any other value enables interval logging and sets the
interval time in seconds. Interval logging means that all
channels
are saved to fl ash periodically with
set interval. This is useful if the fl ash memory need to last as long as possible for given transmitter
count. Maximum value for this setting is 65535s.
This setting dictates only how channel data is saved in to the fl ash memory.
Flash erase
Flash can be erased with this if “clear settings” jumper is set, see page 9. If jumper is not set on
board, this won’t do anything.
Run
This setting is used to stop clock updates to Mekuwin menu, so that new time can be set.
Year, Month, Day, Hour, Min, Sec
These are used to update new time for the device. Maximum for the year is 2063. When new time
is set, “Save to EEPROM”-button near clock menu has to be pressed to update the clock. There is
about 1s delay on setting to the clock from the menu.