Minimum static head - open vented systems. Pumps may be fitted to systems with a
minimum static head of 300mm provided the pump inlet is adjacent to the neutral point
and the water temperature does not exceed 80ºC

2. Packaging & Handling

2.1 Transport and Storage  ATTENTION

The pump must be protected from moisture, and must not be subjected to temperatures
outside -10ºC and 50ºC.

2.2 Handling  ATTENTION

Care must be taken when handling and installing the pump to avoid damaging 
components. If damage occurs the pump must not be used Abnormal handling may
invalidate the warranty

3. Description of Pump

3.1 General Description

The pump is fitted with a wet running motor. The pumping fluid lubricates the bearings
and rotor.

Design and Function / Safety Devices

The motor windings are impedance protected. 
A provision for earthing the outer casing is provided.

Standard Pumps

Models offer a single or variable speed setting to allow system requirements to be 
accurately met.

Electronic Pumps

The pump control channel is selected using a 3-stage selector switch in accordance with 
the installation requirements

Prohibited Use  ATTENTION

The pump must not be used on secondary hot water services, handling drinking water or
food related liquids.

4. Installation

4.1 Electrical Connection Block Positioning

If the electrical connection block is not in a convenient position when the circulator is
delivered, the motor head may be rotated prior to fitting. Release the screws on the pump
casing and rotate the motor head to its new position.

If this is done please check the following: -

1. Take care not to remove or damage the seal between motor head and pump casing.

2. Tighten the fixing screws in a diagonal pattern in stages to a final torque of 25Kg cm

(22lb in).

9

GB

8573 Nocchi Booklet 12 linguil 4124349:Pentair Water Italy Srl - Reb

Summary of Contents for R2SE

Page 1: ...uik en 32 onderhound 38 Manual de utilizi o e manuten o 44 K itt ja kunnssapito 50 Bruks och underh lls anvisningar 56 Uputsvo za upotrebu i odrzavanje 62 Instruksjonsh ndbok og vedlikehold 68 I F GB...

Page 2: ...sabilit que les produits de la s rie SR3 R2SE sont conformes aux Conditions Essentielles de S crurit et de Tutelle de la Sant selon les Directives 98 37 73 23 89 336 et leurs modifications suivantes P...

Page 3: ...iceras i direktiven 98 37 73 23 89 336 och senare till gg SR3 R2SE PENTAIR PUMPS S p A intygar under sitt eget ansvar att elpumparna nedan SAMSVARSERKL RING Firmaet Pentair Water Italy Srl erkl rer un...

Page 4: ...domestic central heating systems only 1 2 Product Data SR3 xx 40 SR3 xx 50 SR3 xx 60 SR3 25 70 R2SE ConnectionVoltage 1 230V 10 50Hz 1 230V 10 50Hz 1 230V 10 50Hz Insulation class H 1800 C H 180 C F 1...

Page 5: ...for earthing the outer casing is provided Standard Pumps Models offer a single or variable speed setting to allow system requirements to be accurately met Electronic Pumps The pump control channel is...

Page 6: ...ng a pump maintain the same direction of flow 4 3 Electrical Connections ATTENTION Electrical work to be carried out by a competent qualified and licensed electricians in strict conformity to ruling n...

Page 7: ...ent air within a short while of switching on In cases where the pump venting is slow identified by pump noise the pump bearings may be quickly vented by using a the manual restart knob Switch off the...

Page 8: ...guarantee efficient operation of the heating installation and optimum adaptation of the pump to the load on the hydraulic installation it is important to select the right control range The pump contro...

Page 9: ...ressure within the permissible limits Pump may require 48 hours to attain normal quiet operation Locked Pump Should the pump fail to start switch to maximum setting If the pump still does not start th...

Reviews: