OPERATION
14
Speed Scrub 2001HD (09--04)
7. Change or turn over pad when worn.
8. Stay clear of floor obstructions, such as electrical
plates or grates, they will destroy pad.
9. During brief stops, you do not have to turn off any
switches, the brush and solution flow will
automatically stop when control grips are
released.
10. Periodically check battery meter discharge level.
When the needle drops to the red zone, recharge
batteries.
ATTENTION: Do not continue to run machine
when battery meter needle is in the red zone,
battery damage will result.
11. While cleaning, view sight gauge at rear of
machine for remaining cleaning solution. Each
mark on hose indicates 19L (5 gal).
12. When solution tank runs dry, turn off brush switch,
raise brush and continue to vacuum until all dirty
water is consumed. Then drain recovery tank
(See DRAINING TANKS)
.
STOPPING MACHINE
1. Turn off brush switch, raise brush and continue to
vacuum until all dirty water is consumed.
2. Release control grips.
3. Raise squeegee and scrub head.
4. Turn off switches.
FOR SAFETY: Before leaving or servicing
machine, stop on level surface and turn off
machine.
EMERGENCY STOPPING (OPTION)
Strike the emergency stop button, located on the
control panel, to stop the machine in an emergency.
Turn the button clockwise to reset (Figure 22).
FIG. 22
CIRCUIT BREAKERS
The machine is equipped with circuit breakers to
protect the machine from damage.
If circuit breakers should trip, they will not reset
immediately upon tripping. Determine reason why
breaker tripped, allow motor to cool and reset.
Brush motor circuit breaker will trip due to excessive
overload on pad. Reduce pad pressure or replace pad
if breaker should trip. Brush motor (35 amp) circuit
breaker is located near the charger plug.
The main (10 amp) and drive/vacuum (35 amp) circuit
breakers are located at rear of machine (Figure 23).
FaST Model
Brush
Motor
Circuit
Breaker
FIG. 23