OPERATION
10
Speed Scrub 1701/2001/2400 (11--97)
DRAINING TANKS
1. Turn all switches to the “OFF” position. Unplug
power cord for electric models.
2. Raise squeegee and brush head and transport
machine to nearest floor drain.
NOTE:
If using bucket to drain machine, do not use
same bucket for filling solution tank.
DRAINING RECOVERY TANK
Recovery tank must be emptied every time before
refilling solution tank. To drain recovery tank perform
the following steps:
WARNING: If recovery tank is not emptied
between fill ups, foam or water will enter the
vacuum standpipe and damage vacuum motor.
Float shut--off will not keep foam out of standpipe.
Vacuum damage due to foam or water is not
covered by warranty.
1. Remove drain hose from holder, position hose
over floor drain and twist off drain hose plug. To
completely drain recovery tank, hinge open tank
sideways and flip up tank support stand to rest
tank on
(Figure 18).
FIG. 18
2. Rinse recovery tank after each use. This will
prevent a foul odor. Unscrew clear lid on recovery
tank. Use a hose to rise out the recovery tank. Be
careful not to spray water into float shut-off.
3. Replace drain hose plug tightly when tank is
empty.
DRAINING SOLUTION TANK
To drain leftover cleaning solution from solution tank
follow the steps below:
1. Pull clear gallon marker hose off hose barb at rear
of machine and drain solution into floor drain or
bucket
(Figure 19).
FIG. 19
2. Flush solution tank with clean water after each
use. This will prevent clogging due to chemical
buildup. Let clean water drain out through clear
hose.
3. Push solution flow lever forward to rinse out
solution flow system.
4. Reconnect clear hose to hose barb. Be certain
hose is completely pushed on hose barb.
To Order Parts Call 1-888-702-5326 - https://monsterfloorequipmentparts.com