OPERATION
Speed Scrub
t
2001 Battery (11–01)
7
FIG. 6
8.
Raise brush head. To raise brush head, step down
firmly on the bottom brush lift foot pedal until brush
locks into the raised position (Figure 7).
FIG. 7
FILLING SOLUTION TANK
1.
Push machine to fill station. Raise squeegee and
brush head when transporting.
2.
Pull solution flow lever completely back to shut off
solution flow (Figure 8).
FIG. 8
3.
Open solution fill door at front of machine and fill
solution tank with 38L (10 gal) of clean water,
60
°
C (140
°
F) maximum temperature. Or use the
rear fill port to fill solution tank. The clear tube
below the fill port has 19L (5 gal) increment
markers to indicate amount of water in tank
(Figure 9).
WARNING: Flammable materials can cause
an explosion or fire. Do not use flammable
materials in tank(s).
FIG. 9
NOTE: If filling with a bucket be certain that bucket is
clean. This will prevent the chance of clogging the
solution lines.
4.
Add cleaning detergent according to mixing
instructions on bottle.
FOR SAFETY: When using machine, follow
mixing and handling instructions on chemical
containers.
ATTENTION: Use only recommended cleaning
detergents, DO NOT use substitutes. Consult an
authorized distributor for cleaning detergent
recommendations.