OPERATION
7
265XP
(03-99)
FIG. 2.
ATTENTION: Do not operate scrub motors
without brushes or pad drivers (with pads) in
place.
SQUEEGEE TOOL INSTALLATION
Slide the squeegee tool onto the bracket, with the
wing screws loose. MAKE SURE the washers are on
top of the bracket. Tighten the wing screws (HAND
TIGHTEN ONLY). If they are too tight, this will defeat
the breakaway feature should the tool get caught on
an obstruction during use. Attach the pickup hose to
the tool (Figure 3).
FIG. 3.
FILLING THE SOLUTION TANK
Tanks on the machine are made of polyethylene and
are resistant to most cleaning solutions. CAUTION:
DO NOT USE WATER IN EXCESS OF 66
°C
(
150
°
F), as it can cause the material to become brittle
and void the warranty.
Remove the clear lid from the solution tank
(operator’s left) and pour solution to the fill line
located inside the tank. If powdered chemicals are
being used, mix the chemical with water before
putting it in the tank. This will help prevent clogging of
plumbing, valves, etc.
WARNING: Flammable materials can cause
an explosion or fire. Do not use flammable
materials in tank(s).
MACHINE OPERATION
1. Turn the ignition key to the ”ON” position.
2. Activate Scrub/Transport Switch to either
transport (brush–up) or scrub (brush down)
position (Figure 4).
FIG. 4.
To Transport:
Press bottom half of Scrub/Transport Switch to
raise brush if you wish to transport the machine
without scrubbing.
To travel, twist the control grips forward. As you
twist farther, the machine will travel faster.
To stop, simply release the grips.
For reverse travel, twist the grips backward.
Reverse travel speed is limited for safety.
To Scrub:
Press and release the top half of Scrub/Transport
Switch to lower brushes for scrubbing. The scrub
head will lower to the floor and automatically select
a pre–determined pressure, approximately 75 lbs.
This setting is sufficient for most applications. If this
pressure is right for your job, no additional operator
settings are required.