OPERATION
8
Power Eagle
t
1016/1020 Plus (03--06)
DRAINING TANKS
FOR SAFETY: When servicing machine, unplug
cord from wall outlet.
ATTENTION: Use different buckets to fill and drain
machine to prevent solution system clogs.
DRAINING RECOVERY TANK
1. Turn off machine and unplug power cord.
2. Turn drain hose knob counterclockwise and pull
out plug to drain (Figure 8).
FIG. 8
3. After draining, replace drain hose knob securely.
DRAINING LEFTOVER CLEANING SOLUTION
1. Disconnect vacuum hose from recovery tank
dome and replace with .9m (3 ft) clean--out hose,
supplied with machine (Figure 9).
FIG. 9
2. Turn on Vacuum/Pump switch.
3. Remove solution tank lid and vacuum out leftover
solution.
4. Drain recovery tank.
MACHINE MAINTENANCE
To keep machine in good working condition, simply
follow machines daily, weekly and monthly
maintenance procedures.
FOR SAFETY: When servicing machine, unplug
cord from wall outlet.
DAILY MAINTENANCE
(Every 4 Hours of Operation)
1. Drain and rinse out recovery tank thoroughly
(Figure 10).
FIG. 10
2. Remove and clean float shut--off screen, located in
recovery tank (Figure 11).
FIG. 11